This is an 800mm (2.5 ft) cable used to link MLA or MLA Compact cabinets in an array.
PWA00039
This is a 3m (10ft) cable for linking MLX or DSX subs.
PWA00051
A 5m (16ft) cable for short runs to ground stacked systems where a rack is positioned close to the cabinets
PWA00063
A 15m (50ft) cable for longer runs from racks to ground stacked arrays. Also suitable for Ethernet linking
between Master and slave racks across stage in smaller venues.
PWA00057
A versatile 35m cable for U-Net connection from a Master or Slave Rack up to the first and last cabinets in a
flown array, usually as part of a loomed cable bundle. It is also frequently used as an Ethernet cross-stage link between stages in
larger venues and even as an Ethernet connection from the Master rack to Front of House in smaller venues.
PWA00052
This is a 75m (246ft) cable supplied on a drum. It can be used to build longer array looms for very large arenas
or those where a cable pick has to be employed to avoid site-line issues. It can also be used as an Ethernet cross stage link
between racks for very large stages at Stadium or festival events. Finally it can be used as the Ethernet connection to Front of
House from the Master rack.
PWA00041
This is a 120m cable (390ft) that is available as an optional accessory; it is not supplied with any standard
systems. It may be used for U-Net connections where exceptionally long cable runs are required. It is the longest run that U-Net
supports so cannot be joined to make it longer or via the parallel link connection on the patch panel. It
MUST
NOT
, under any
circumstances be used for Ethernet connections, Ethernet is not supported over cable lengths greater than 100m.
Adaptors
There are three adaptors available for use with Network cables to assist with connectivity.
PCX00048
This is an ODU to ODU barrel connector housed in a Neutrik D-Type module housing. This can be used to
extend U-Net or Ethernet cables.
PCX00043
This is an ODU to RJ45 barrel connector also housed in a Neutrik D-Type module housing. Typically this would
be used to connect to the PC at Front of house using the 75m ODU network cable connected to the Master rack and using the
PCX00043 in conjunction with a short Cat5e patch cable to connect to the Ethernet port on the PC.
PWA00056
This is a 10m rugged Cat5e cable, one end is terminated in an ODU connector, the other in a standard RJ45.
This can also be used to connect a PC to a Master rack, either directly when the PC is close to the rack during set-up or using the
Summary of Contents for MLA
Page 1: ...User Guide Multi cellular Loudspeaker Array MLA ...
Page 115: ...MLA System USER GUIDE MLA System User Guide V2 1 115 ...
Page 117: ...MLA System USER GUIDE MLA System User Guide V2 1 117 ...
Page 152: ...MLA System USER GUIDE MLA System User Guide V2 1 152 This is the response on the ceiling ...
Page 215: ...MLA System USER GUIDE MLA System User Guide V2 1 215 ...
Page 258: ...MLA System USER GUIDE MLA System User Guide V2 1 258 ...
Page 413: ...MLA System USER GUIDE MLA System User Guide V2 1 413 ...
Page 420: ...MLA System USER GUIDE MLA System User Guide V2 1 420 ...
Page 421: ...MLA System USER GUIDE MLA System User Guide V2 1 421 ...
Page 438: ...MLA System USER GUIDE MLA System User Guide V2 1 438 ...
Page 440: ...MLA System USER GUIDE MLA System User Guide V2 1 440 ...
Page 447: ...MLA System USER GUIDE MLA System User Guide V2 1 447 ...
Page 454: ...MLA System USER GUIDE MLA System User Guide V2 1 454 ...
Page 455: ...MLA System USER GUIDE MLA System User Guide V2 1 455 The finshed 6 box ground stack system ...