![Marsh PatrionPlus Technical Manual Download Page 209](http://html1.mh-extra.com/html/marsh/patrionplus/patrionplus_technical-manual_1730813209.webp)
Repair
7-25
7) Set the printhead assembly on a clean, flat surface.
8) Disconnect the LED connector from the CPU board. (See Figure 7X.)
9) Remove the four screws holding the CPU board to the printhead back
10) Remove and retain the o-ring from the female data line connector.
Figure 7X: Removing the LED Connector
Figure 7Y: Removing the Back Plate
CPU Board
LED
Note: Some components have been
removed for illustration purposes.
LED Connector
CPU Board
Female Data Line
Connector
O-ring
Back Plate
Screw
Summary of Contents for PatrionPlus
Page 41: ...Installation ii 29669 02080 Rev AF...
Page 72: ...Operation iv 29669 02080 Rev AG...
Page 153: ...Maintenance ii 29669 02012 Rev AF...
Page 161: ...Troubleshooting ii 29669 02080 Rev AF...
Page 184: ...Repair ii 29669 02080 Rev AF...
Page 212: ...Parts List ii 29669 02080 Rev AF...