![Marsh PatrionPlus Technical Manual Download Page 177](http://html1.mh-extra.com/html/marsh/patrionplus/patrionplus_technical-manual_1730813177.webp)
Troubleshooting
6-16
3) Disconnect the ink line, data lines and power supply cables from the
printhead.
4) Remove the ground wire. (See Figure 6C.)
5) Remove the printhead enclosure.
6) Remove the printhead assembly from the case. (Nozzle blocks must be
removed with the printhead assembly.) Take care not to stress the ink
lines.
7) From your Backflush Kit, obtain the large syringe (60cc).
8) Cut 3/8" (0.95 cm) of ink tubing and attach it to the large syringe.
Figure 6C: Removing the Printhead Assembly
Valve Driver
Board
Back Plate
Screw
Printhead
Enclosure
Valve Tree
Nozzle Block
Ground Strap
Ground Wire
Screw
Printhead Cover
Nozzle Block
Slot