Operations
4-42
4) Highlight RS-232 Insert, then press Enter. The RS-232 Insert screen is
displayed.
5) Highlight each field and enter the appropriate information.
6) Press Add to Message to add the element to the message.
Information Fields
Description
Field Offset
Given a string of characters from an external device, the
field offset determines where the element begins.
Number of
Characters
Given a string of characters from an external device, the
number of characters indicates how many characters apply
to the element.
Default Data
The default data is added to the message you are creating
to represent the RS-232 insert. The default data also
designates the total amount of space allowed for the insert.
If the default data does not reserve enough space in the
message, the last characters of the insert might not print.
Different letters can occupy different amounts of space. For
example, in 16 Dot font i’s occupy less space than W’s. (All
numbers use the same space.) It is recommended that you
enter all W’s as the Default data to reserve the maximum
amount of space. Make sure the number of W’s in the
Default data field matches your entry in the Number of
Characters field.