Harness 3: White 9-Pin Mini Connector
Yellow Wire: (-) 200mA Ignition 3 Output
This wire provides a 200mA (-) ground output that becomes active 4 seconds before the
remote start unit initializes, and remains grounded while the engine is running.
Note: This wire can also be used for an immobilizer bypass module.
Ignition 3 Output:
Some newer vehicles use a third ignition wire which is required to start and keep the vehicle’s engine running. If
this is the case, wire a relay (not supplied) as shown. Do not connect any vehicle circuits together, they are
isolated for a reason.
Transponder Interfacing Using ALA984 Relay:
If the vehicle has a transponder system installed, you will need to bypass the system while the vehicle is
operating under the control of the Remote Start Unit. To do this, follow these steps:
1. You will need a transponder key that’s already programmed to the vehicle.
2. Remove the trim around the ignition switch.
3. Wrap a thin (30 awg) wire tightly around ignition switch 6 to 8 times and secure it.
4. About 6" down line make another loop of approximately 2" diameter.
5. Place the key inside this loop and secure it to the loop.
6. Connect on end of the 30 awg wire to pin (87) of the relay module.
7. Connect the other end of the loop wire to Pin (30) of relay module.
8. Connect (86) to ignition, connect (85) to the yellow wire of white 5-pin mini connector.
5
Wiring
87
87a
86
85
30
Yellow
Wire
+12 V Constant
Fused 25A Capable
Ignition 3 Wire from
Ignition Key Switch
White
9-Pin Mini
Connector
M6A-IM 3/10/05 2:43 PM Page 5