AVS A-SERIES INSTALLATION MANUAL - GEN 2 VER 5
24
Programming functions Register 2
continued
Vehicle set up: Open a door, close bonnet & boot, arm & disarm alarm then turn ignition
on, off & on.
Feature:
Indicator flash on alarm trigger
Press the
button
this many times:
6
Factory setting:
ON
Description:
When turned OFF, this feature prevents the indicators from flashing when the
system is triggered. The indicators will still flash on arm and disarm as well as in
panic mode.
Feature:
Extended lock pulse
For central closure
Press the
button
this many times:
7
Factory setting:
OFF
Description:
When this feature is turned ON, the lock output becomes a 15 second pulse
instead of 0.5 seconds. For use with vehicles with vacuum central locking or those
with a central closure wire (some BMW, Mercedes) i.e. doors lock, electric windows
wind up, sunroof closes automatically.
Feature:
Extended unlock pulse
Press the
button
this many times:
8
Factory setting:
OFF
Description:
When this feature is turned ON, the unlock output becomes a 15-second negative
pulse instead of 0.5 seconds. This feature is for use with vehicles with vacuum
central locking.