AVS A-SERIES INSTALLATION MANUAL - GEN 2 VER 5
35
Trouble shooting guide
Problem
Possible fix
No flash on arm/disarm
or
Arms on lock/unlock button, disarms on boot button
Turn OFF Factory Remote Interface feature
Register
1, Feature 19
Arms/disarms off boot button
Turn OFF
Register 2, Feature 2
Alarm chirps for 10 seconds on opening a door
before triggering
Turn OFF
Register 1, Feature 21
(Keypad disarm
mode, not in manual).
No output on:
•
central locking
•
boot release
•
indicator flash etc
Polyfuse may have tripped. Check circuit for
excessive current draw or short. Polyfuse may take
several minutes before resetting. Wait and re-test.
Turbo timer problems
No engine shut down on boot button
Engine only runs for 10 seconds
Turn ON
Register 1, Feature 17.
Register 1, Feature 16.
Enter programming. Then
after turning ignition off, push the boot pop button
again (siren will beep) to set to 1 minute. Then turn
key ON then OFF to set.
MAP upgrade problems
Upgrade loom does not work in enable or inhibit
modes
In enable mode, nothing happens when I pulse the
motor wires
Turn on
Register 1, Feature 14.
Make sure POS2 is getting a positive enable signal
when the motor wires pulse or constant.