AVS A-SERIES INSTALLATION MANUAL - GEN 2 VER 5
20
Programming features Register 1
continued
Vehicle set up: Close all doors, bonnet & boot, arm & disarm alarm then turn ignition
on, off & on.
Feature:
Factory remote interface mode ON/OFF
Refer Factory Remote interface (MAP function) for full details
Press the
button
this many times:
14
Factory setting:
OFF
Description:
When this feature is ON it enables the factory remote interface wires to be used
for the MAP upgrade. When OFF the wires are disabled to prevent unauthorised
disarm via the upgrade wires.
Feature:
Voltage drop sense override
Press the
button
this many times:
15
Factory setting:
ON (to activate voltage drop turn feature off)
Description:
When ON, this feature prevents the alarm triggering via sensing a drop in
voltage in the vehicle’s electrical system. This may be necessary where engine
thermo fans cut in automatically or there are other accessories active even when
the ignition is turned off e.g. car phones. TO ACTIVATE VOLTAGE DROP TURN
FEATURE OFF.
Feature:
Turbo timer run time
Press the
button
this many times:
16
Factory setting:
OFF
Description:
This feature is used for setting the run time for both interface and onboard turbo
timers. The siren should chirp the current setting on entering and the new setting
on exiting this mode. Refer to Turbo Timer Instructions.
Feature:
On-board turbo timer
Press the
button
this many times:
17
Factory setting:
OFF
Description:
When turned ON this feature activates the on-board turbo timer which allows
the turbo timer to be shut down early via the
button.
To set up the on-board turbo timer refer to Turbo Timer Instructions.
Feature:
Delayed panic
Press the
button
this many times:
18
Factory setting:
ON
Description:
When this feature is ON the
button needs to be held for 3 seconds to
activate panic instead of being instant. Pressing the
button again once
will disarm panic mode.