background image

             AVS A-SERIES INSTALLATION MANUAL - GEN 2 VER 5 

 

19 

The last memory heard is the most recent alarm sector triggered. Turn the ignition 
on and off to exit this mode. 

  

 

Summary of Contents for AVS 4406037

Page 1: ...A5 Certification Test Report XF2106 R2 This product complies with AS NZS 3749 1 2003 Class A Volumetric Sensing glass break shock must be enabled to comply with a Class A installation refer Programmab...

Page 2: ...elligent glass break sensor AVS A5 6 Remote controls Learning new remotes Learning new remotes when no working remotes are available Deleting remotes 7 Emergency disarm PIN code override 7 Wiring inst...

Page 3: ...xtended lock pulse Extended unlock pulse Anti hijack mode 1 Anti hijack mode 2 Alarm on anti hijack trigger Single relay cut on anti hijack activation LED flash on pending anti hijack activation 16 17...

Page 4: ...it may be too high The polyfuse may take several minutes to reset Auto immobilisation The AVS system will automatically immobilise 38 seconds after the ignition is switched OFF The LED will light soli...

Page 5: ...ash and the siren will sound To cancel panic mode press the button again once or push the button once Note this button will also disarm the alarm The panic feature will not work when the ignition is s...

Page 6: ...This means for example if you arm the alarm with the door open the alarm will trigger if the door closes Turbo timer functions The system has two turbo timer functions On board turbo timer allows the...

Page 7: ...re is disconnected If the alarm is armed or auto immobilised the siren WILL sound if the battery or digital data wire is disconnected Original DBBSM sirens can be used on V5 alarm modules but will beh...

Page 8: ...lost remote you have three options 1 Use Learning remotes when no working remotes are available sequence above 2 A new remote can be coded into the system 12 times You can do this by coding the same...

Page 9: ...is correct the alarm will disarm Start the vehicle within 40 seconds or the alarm will automatically immobilise and you will need to repeat the procedure NOTE Unless a remote control is learnt in you...

Page 10: ...ate it is possible to trace the required wires by first un clipping the case Next slide the circuit board out to expose the main connector plug Use the following connector diagram below to trace each...

Page 11: ...be found with other alarm wires marked with red and white sheathing Green this wire gives a constant 200mA negative output alarm when the alarm is triggered It can be used to run additional piezo sire...

Page 12: ...sounding the siren for 30 seconds NOTE This wire will not give siren chirps for arm disarm confirmation 7 BOOT OUT This gives a 1 second negative output for boot release 150ma maximum For use where e...

Page 13: ...M2B wires To meet AS NZS installation standards make sure the cut is made more than 300mm from the starter or fuel pump immobiliser cuts IM3A 2 wires and IM3B 2 wires Fuel pump immobiliser circuit The...

Page 14: ...AVS A SERIES INSTALLATION MANUAL GEN 2 VER 5 15...

Page 15: ...d turned off the siren will chirp twice Programming features Register 1 Vehicle set up Close all doors bonnet boot arm disarm alarm then turn ignition on off on Feature Arm and disarm chirp Press the...

Page 16: ...AVS A SERIES INSTALLATION MANUAL GEN 2 VER 5 17 Description When this feature is ON the ARM wire changes to become negative on alarm instead Can be used to power pagers or internal sirens...

Page 17: ...es 12 Factory setting SELECT the mode required Description This mode allows the installer to verify that each trigger of the alarm system is working without having to arm and disarm the system each ti...

Page 18: ...AVS A SERIES INSTALLATION MANUAL GEN 2 VER 5 19 The last memory heard is the most recent alarm sector triggered Turn the ignition on and off to exit this mode...

Page 19: ...ne thermo fans cut in automatically or there are other accessories active even when the ignition is turned off e g car phones TO ACTIVATE VOLTAGE DROP TURN FEATURE OFF Feature Turbo timer run time Pre...

Page 20: ...AVS A SERIES INSTALLATION MANUAL GEN 2 VER 5 21...

Page 21: ...with the engine running and arm the alarm The alarm will be fully armed three seconds after pressing the button If the alarm is activated the system will shut the engine down and trigger as normal Whe...

Page 22: ...SERIES INSTALLATION MANUAL GEN 2 VER 5 23 opened within 60 seconds If turned on dome light extension will be turned off automatically Installers must wire up the door circuit for this feature to func...

Page 23: ...de Feature Extended lock pulse For central closure Press the button this many times 7 Factory setting OFF Description When this feature is turned ON the lock output becomes a 15 second pulse instead o...

Page 24: ...on wire Many vehicles have dual ignition wires to run cooling fans You must ensure the cooling fans continue to run when the vehicle is running on the turbo timer you may need to hook up the second ig...

Page 25: ...run time There are four levels each level is indicated by the number of chirps See table below 6 Once the desired time duration is selected simply turn the ignition on then off The siren should chirp...

Page 26: ...l arm the alarm and lock the doors as normal but the immobiliser relays will stay closed until the pre programmed time out If the alarm detects an intrusion the alarm will sound and the system will im...

Page 27: ...ement the maximum run time allowed for the turbo timer There are four levels each level is indicated by the number of chirps See table below It is very important that the external turbo timer does not...

Page 28: ...switch to disarm the alarm Inhibit mode is a much more secure upgrade option The table below describes each upgrade wires operation Wire Inhibit mode Enable mode POS1 Positive arm arms the alarm when...

Page 29: ...er as normal When in courier mode the glass sensor AVS A5 will be disabled however AUX input remains active when the engine is running but will arm normally when the ignition is off Note The ignition...

Page 30: ...ehicle Connect to lock wire of vehicle 2 Positive pulse CDL system Cut Cut Unlock NC Unlock COM Unlock NO Lock NC Lock COM Lock NO Earth Earth Connect to unlock wire of vehicle Connect to lock wire of...

Page 31: ...stem Unlock NC Unlock COM Unlock NO Lock NC Lock COM Lock NO Vehicle s Existing CDL Switch Vehicle s Existing Door Motor Cut Cut Earth Connect to relay side of control wire Connect to Unlock COM 5 Sin...

Page 32: ...nd N O contacts only on channel 4 The RCX 4 can also receive these signals and will put out a basic low current negative Note If you want to use the alarm boot pop or alarm panic channel be aware that...

Page 33: ...AVS A SERIES INSTALLATION MANUAL GEN 2 VER 5 34 RXPRO Ch 2 Boot pop or T T shut off RXPRO Ch 3 Alarm panic...

Page 34: ...yfuse may have tripped Check circuit for excessive current draw or short Polyfuse may take several minutes before resetting Wait and re test Turbo timer problems No engine shut down on boot button Eng...

Reviews: