Summary of Contents for TW-9010

Page 1: ...TOMAHAWK TW 9010 TOMAHAWK CAR ALARMS TW 9010 Two Way Car Alarm System USER MANUAL INSTRUCTIONS FOR INSTALLATION ...

Page 2: ... Car searching Remote shock sensor disabling Alarm modes Panic mode Anti hijack mode Valet mode Call driver Override button functions Emergency arming disarming Remote start up preparation for cars with manual transmission Programming auxiliary trinkets LED indicator operation modes Trinket pager battery replacement Programming mode Programming trinket pager functions Programming table Description...

Page 3: ...or Automatic engine warm up to specified temperature Daily 1 2 4 12 hour automatic start up Defective area bypass with visual and sound confirmation Two zone shock sensor Remote shock sensor disabling Protection against mis operations Self diagnostics 3 extra channels Anti hijack mode Panic mode Valet mode Doors hood and boot security Trinket pager battery charge indication Trinket pager battery p...

Page 4: ...TOMAHAWK TW 9010 2 Remote Control Trinkets 3 ...

Page 5: ... 3 1 security mode indication 2 silent security mode indication 3 closed central lock indication 4 open central lock indication 5 open door s indication 6 open hood indication 7 open boot indication 8 parking lights flashing indication 4 ...

Page 6: ...n 12 driver call indication 13 warm up to specified temperature mode indication 14 daily auto start indication 15 light shock indication 16 strong shock indication 17 1 shock sensor warning zone disabling indication 17 2 shock sensor disable indication 18 Anti Hijack mode indication 19 vibration mode indication 20 Valet mode indication 5 ...

Page 7: ... icons and In case when siren sounds 3 CHIRPS it means that the system detected and disabled a defective zone open door hood boot or hand brake disengaged The system will automatically take this zone for protection as soon as the zone is repaired door hood boot closed and hand brake engaged 5 Arming Mode with Siren Disabled To arm a car without siren sounds all messages and confirmations will be s...

Page 8: ...g Table LED indicator glows continuously in this mode In this mode engine start up with ignition key is not possible To exit the immobilizer mode press button 1 time or switch ignition OFF and press button OVERRIDE 1 time 8 Disarming To disarm vehicle press button 1 time Parking lights will flash 2 times siren will sound 2 CHIRPS if the system is not in security mode with siren disabled to confirm...

Page 9: ...bo Timer Tomahawk TW 9010 provides a turbo function for vehicles with turbo engines If this function is enabled the engine keeps on running after ignition OFF for 1 3 or 6 min see Programming Table 12 Remote Engine Start up Press button Parking lights will flash 3 times siren will sound 3 CHIRPS LCD will display the following icons 1 engine start up attempt 2 if engine fails to start for any reaso...

Page 10: ...ne to Specified Temperature Tomahawk provides for an auxiliary temperature sensor for installation under the hood see Diagram No 10 If this sensor is installed engine start and warm up is performed by this sensor s data otherwise by the cabin temperature sensor data To enable this function press and hold buttons and simultaneously Parking lights will flash 1 time and siren will sound 1 CHIRP to co...

Page 11: ...ody will play After this function is enabled beginning from the next day the system will automatically start engine at the time of enabling To disable the daily start up function press buttons and Parking lights will flash 2 times and siren will sound 2 CHIRPS to confirm disabling the function LCD will hide icon and a melody will play To enable 1 2 4 and 12 hour start up it is necessary to enable ...

Page 12: ...ar Search To enable this function press and hold buttons and simultaneously Parking lights will flash 6 times and siren will sound 6 CHIRPS to show car location 20 Remote Shock Sensor Cut off To enable this function while in security mode press and hold buttons and simultaneously LCD will display icon to show that the shock sensor warning zone is disabled Second press on the buttons will disable t...

Page 13: ...o your car 23 Anti Hijack Mode To enable this function press and hold buttons and simultaneously Parking lights will flash for 30 sec then the system will enable alarm mode engine starter will be locked LCD will display icon and an alarm signal will sound To disable this mode press button This mode can be also enabled using button Anti hijack Press button Anti hijack car engine must be started Par...

Page 14: ...6 Override Button Functions Some of TOMAHAWK TW 9010 functions can be enabled without control trinkets To enter this mode do the following 1 Switch ignition OFF 2 Using Override button to select required function A Valet mode 3 times B Daily auto start 4 times C Auto warm up to specified cabin temperature 5 times 3 Switch ignition ON 4 The system will confirm the selected function with siren CHIRP...

Page 15: ...nd siren will sound 1 CHIRP to confirm the function enabling 20 sec later the system will enable security mode NOTE If 20 sec after emergency arming any of security zones is triggered the system will alert you with 4 parking light flashes and 4 siren CHIRPS providing you 20 sec to disarm the car If disarming does not take place the system will enable alarm mode 2 For emergency disarming A Switch i...

Page 16: ...d close the door If all the steps are performed correctly the system will automatically stop the engine if not capability of remote start up will be disabled 29 Programming Auxiliary Trinkets TOMAHAWK TW 9010 provides for recording up to 4 remote control trinkets in its memory To record perform the following 1 Switch ignition ON engine should not be started 2 Press and hold button Override 3 Wait ...

Page 17: ...r mode Glowing continuously 2 Car disarmed Disabled 3 Car armed 1 flash 4 Daily auto start mode 2 flashes 5 Auto warm up to specified temperature mode 3 flashes 6 Daily auto start mode and Auto warm up to specified temperature mode 4 flashes 7 Valet mode 5flashes 31 Trinket pager Battery Replacement If battery charge indicator looks like that it means the battery is low and needs prompt replacemen...

Page 18: ... OFF 6 siren CHIRPS will confirm entry in programming mode Use button Override to select required function Each press means change to the next function The system will indicate selected function with siren CHIRPS Short CHIRP 1 Long CHIRP 5 EXAMPLE 14 button Override presses 2 long and 4 short CHIRPS function 14 is selected See numbers and descriptions of functions in Programming Table 17 ...

Page 19: ... scrolling Setting hour minute backward Hold for fast scrolling Clock setting mode hour 1 time Clock setting mode minutes 2 times Alarm clock setting mode hour 3 times Alarm clock setting mode minutes 4 times Alarm clock setting mode ON OFF 5 times Timer setting mode hour 6 times Timer setting mode minutes 7 times Timer setting mode ON OFF Alarm clock setting mode 1 time Timer setting for 10 min 2...

Page 20: ...ore gasoline diesel engine start sec 2 10 10 10 9 times 1L 4S CHIRPS Duration of central lock opening closing impulse sec Ver 1 Ver 2 Ver 3 Ver 4 10 times 2 long CHIRPS Two step door opening or 3rd auxiliary channel immobilizer Ver 1 Ver 2 Ver 3 Ver 4 11 times 2L 1S CHIRPS Safe driving function OFF Ver 1 Ver 2 Ver 3 12 times 2L 2S CHIRPS Auto arming Ver 1 Ver 2 Ver 3 13 times 2L 3S CHIRPS Cabin li...

Page 21: ...tion control versions Version 1 by vehicle network voltage Version 2 by oil pressure sensor Version 3 by tachometer ATTENTION If you choose 3rd version of engine operation control it is necessary to program idle run RPM as follows 1 Disconnect all power users on the vehicle such as conditioner radio and tape recorder amplifier 2 Switch ignition ON and press button OVERRIDE 9 times 3 Switch ignitio...

Page 22: ...ne start up 2 sec for gasoline engines 10 sec for diesel engines 9 Enabling impulse length for central lock Version 1 Closing impulse 0 8 sec opening impulse 0 8 sec Version 2 Closing impulse 3 6 sec opening impulse 3 6 sec Version 3 Closing impulse 0 8 sec 2 opening impulses 0 8 sec Version 4 Closing impulse 30 sec opening impulse 0 8 sec 10 Choice of functions 3rd auxiliary channel or two step d...

Page 23: ...or switching cabin lighting ON after disarming Version 1 Switching cabin lighting ON for 20 sec after disarming Version 2 Switching cabin lighting ON for 30 sec after disarming Version 3 Closing windows 20 sec after arming Version 4 Closing windows 30 sec after arming 15 Selection of cabin temperature measurement units displayed on trinket pager o C or o F engine auxiliary blocking type black and ...

Page 24: ...mum range combined RF antenna for the cabinet should be placed at the highest point without contact with metal parts and electric wires 2 Siren is installed in the engine compartment at a hard to reach place If you use an independent siren ensure access to service key slot The siren should be installed with horn down to escape moisture entry Wire connections should better be done inside cabin for ...

Page 25: ... ON key position 3 Thin red wire system power supply wire 12V It is connected to ignition battery terminal via 10A fuse 4 Thick red wire remote start up circuit power supply wire 12V It is connected to ignition battery terminal via 40A fuse 5 Yellow wire IGN 1 wire output signal 12V It is connected to ignition lock wire where 12V appears in the Ignition ON key position and does not disappear in th...

Page 26: ... Main Socket 1 Black wire system Ensure reliable contact 2 Blue wire wire for cabin light ON or window UP 300mA when disarming arming system programmable 3 Black and red wire IGN 3 output 300mA while remote start up procedure for arrangement of auxiliary ignition circuits This wire may become necessary if ignition lock of vehicle where the system is installed has more than two ignition circuits or...

Page 27: ...n is switched ON when appears on this wire 10 Green and black wire parking lights power supply wire It is connected via 7 5A fuse 11 Green and yellow wire parking lights power supply wire It is connected via 7 5A fuse 12 Black and white wire programmable auxiliary blocking normally closed normally open 300mA programmable 13 Grey wire siren output 1 5A 14 Yellow and blue wire 3rd auxiliary channel ...

Page 28: ...y wire input for hood sensor 4 PIN shock sensor socket Socket for shock sensor 2 PIN Override button socket Socket for button Override 2 PIN LED indicator socket Socket for LED indicator 5 PIN combined antenna socket Socket for combined antenna 4 Selection of Automatic or Manual Transmission Selection of automatic or manual transmission in TOMAHAWK TW 9010 is done using jumper 1 see wiring diagram...

Page 29: ...NTION Please note that impulse duration for central lock control is a programmable function 6 Setting Shock Sensor Setting is the last installation stage of TOMAHAWK TW 9010 alarm system Set shock sensor sensitivity to minimum Gradually increase sensitivity and knock the car body with your palm to check triggering threshold ATTENTION Excess sensitivity may result in a great number of false trigger...

Page 30: ...TOMAHAWK TW 9010 Wire Connections Fig 4 29 ...

Page 31: ...iagram 1 ATTENTION Connect blocking relay socket according to diode polarity shown in diagram 1 Ignition key position Wire Off ACC Ignition Start System power supply wire Starter wire IGN 1 wire ACC wire IGN 2 wire Power circuit supply wire IGN 3 wire 30 ...

Page 32: ...TOMAHAWK TW 9010 6 PIN central lock connection socket 18 PIN main socket Diagram 2 31 ...

Page 33: ...TOMAHAWK TW 9010 4 PIN shock sensor socket 2 PIN Override button socket 2 PIN LED indicator socket 5 PIN combined antenna socket Diagram 3 32 ...

Page 34: ...TOMAHAWK TW 9010 Connection of auxiliary electric drive Control time 0 8 sec Diagram 4 Central lock positive control Control time 0 8 sec Diagram 5 33 ...

Page 35: ...TOMAHAWK TW 9010 Central lock negative control Control time 0 8 sec Diagram 6 Pneumatic central lock Audi Mercedes Control time 3 6 sec Diagram 7 34 ...

Page 36: ...TOMAHAWK TW 9010 Diagram 8 Diagram 9 35 ...

Page 37: ...TOMAHAWK TW 9010 Diagram 10 36 ...

Page 38: ...r supply circuit thick red wire 30A limited with fuse In power supply circuit thin red wire 10A limited with fuse IGN 1 30A yellow wire IGN 2 30A green wire IGN 3 300mA black and red wire Starter wire 30A black and yellow wire 6 PIN central lock connection socket In contact relay circuit for central lock control 20A limited with fuse 37 ...

Page 39: ...ellow and black wire Auxiliary channel 2 output 300mA yellow and red wire Auxiliary channel 3 output 300mA yellow and blue wire Size lights power supply outputs 7 5A green black and green yellow wires limited with fuses Output to cabin light 300mA blue wire Temporary intervals Service output permanently armed black and yellow wire Auxiliary channel 1 output 1 sec yellow and black wire 38 ...

Page 40: ... Auxiliary channel 3 output 0 8 sec yellow and blue wire Impulse duration for central lock control 0 8 sec programmable 3 6 sec 30 sec This device meets weather requirements under GOST 15150 for UHL 2 version installation inside cabin This device meets electric compatibility requirements under GOST R50789 95 39 ...