ECODRIVE DKC01.1/DKC11.1 Drive Controllers
ECODRIVE DKC drive controllers
4-25
DOK-ECODRV-DKC01/11.1*-PRJ3-EN-P
X3 analog inputs and outputs
The inputs and outputs for operating the analog interfaces are connected
via the supply terminal X3/(1-8).
•
torque reduction
•
setpoint input
•
diagnostics outputs
•
override function for positioning control
The actual position is output either as an incremental, parallel or absolute
value serial via the X3/(9-16) supply terminal.
Analog interface
AP0213.fh5
0,5 mm
2
0,5 mm
2
max. 20 m
CNC
0 V
ext
E1
E2
IRED 1
IRED 2
AK1
0V
AK2
1
2
3
4
5
6
7
8
X3
20k
20k
20k
20k
ADC 12 Bit
-
+
min.
between E1-E2
between E1-0VM; E2-0VM
Input current: E1; E2
Inputs:
max.
Input voltage
± 10 V
0,5 mA
± 10 V
± 15 V
± 15 V
Input resistance
approx. 20 kOhm
Input drift
18 µV/°C
AD-convertor
12 Bit
Resolution per Bit
4,8 mV
Fig. 4-33: Analog setpoint input
Analog setpoint input for
control of speed or torque and
override function