Part Number STH044 10/13
81
Will Not Stop Dispensing
•
Disconnect sensor plug from sensor control board.
•
If the dispensing stops, replace the sensor
•
If the dispensing continues disconnect wires
#59 & #60 from the control board
•
Check resistance across control board contacts
•
Closed = Replace the touchless sensing control
board
•
Open = Dispense control board is not
functioning correctly, check control board relays
Replace the selector switch if ohm readings do not
match all three switch settings.