Part Number STH044 10/13
79
SELECTOR SWITCH
FUNCTION
Selects product dispensed. Ice, Water or Ice and
Water.
CHECK
DISPENSE LEVER ACTIVATED
Step 1
Verify line voltage is present at control board
wires #20 & #22. Note - If a blue indicator light is
energized on the touch pad the control board has line
voltage.
Step 2
Depress each selection on the touch pad.
•
1 or more LED’s do not energize/de-energize
when a selection is pressed - Replace touch pad
•
Each touch pad LED energizes/de-energizes as
selections are pressed - Go to next step
Step 3
Isolate and ohm the ice dispense switch
(Wires #59 & #60). The selector switch closes when
depressed and opens when released.
•
Switch does not close/open when the switch is
pressed/released - Replace switch
•
Switch closes/opens as the switch is pressed/
released - Go to next step
Step 4
Reconnect dispense switch and test both
relays for line voltage:
•
Wires #58 & #54 = Ice Dispense Motor
•
Wires #52 & #56 = Water Solenoid
•
Replace wiring, component or control board as
required.
Summary of Contents for RNS012
Page 2: ......
Page 8: ......
Page 26: ...18 Part Number STH044 10 13 This Page Intentionally Left Blank ...
Page 32: ...24 Part Number STH044 10 13 This Page Intentionally Left Blank ...
Page 48: ...40 Part Number STH044 10 13 9 Lift out ice damper ...
Page 49: ...Part Number STH044 10 13 41 10 Lift out ice strainer ramp ...
Page 50: ...42 Part Number STH044 10 13 11 Turn ice wiper counterclockwise to remove ...
Page 56: ...48 Part Number STH044 10 13 19 Remove ice dispensing wheel by lifting straight out ...
Page 57: ...Part Number STH044 10 13 49 20 Water Reservoir Cover Removal A Push up on cover to snap off ...
Page 62: ...54 Part Number STH044 10 13 This Page Intentionally Left Blank ...
Page 110: ...102 Part Number STH044 10 13 This Page Intentionally Left Blank ...
Page 116: ...108 Part Number STH044 10 13 This Page Intentionally Left Blank ...
Page 122: ...114 Part Number STH044 10 13 This Page Intentionally Left Blank ...
Page 123: ......