Part Number STH044 10/13
67
WATER SYSTEM CHECKLIST
A water-related problem could cause component
misdiagnosis.
Water system problems must be identified and
eliminated prior to replacing other components.
Possible Problem List
Corrective Action List
Water area (evaporator) is
dirty.
Clean as needed.
Water inlet pressure not
between 20 and 80 psig.
Install a water regulator
valve or increase the water
pressure.
Incoming water temperature
is not between 45°F (1.7°C)
and 90°F (32.2°C).
If too hot, check the hot
water line check valves in
other store equipment.
Water filtration is plugged (if
used).
Install a new water filter.
Vent tube is not installed on
water outlet drain.
See installation instructions.
Hoses, fittings, etc., are
leaking water.
Repair/replace as needed.
Water float valve is stuck
open or closed.
Clean/replace as needed.
Dump valve is leaking.
Clean dump valve.
Ice machine will shut off on
Low Water SafeGuard.
Summary of Contents for RNS012
Page 2: ......
Page 8: ......
Page 26: ...18 Part Number STH044 10 13 This Page Intentionally Left Blank ...
Page 32: ...24 Part Number STH044 10 13 This Page Intentionally Left Blank ...
Page 48: ...40 Part Number STH044 10 13 9 Lift out ice damper ...
Page 49: ...Part Number STH044 10 13 41 10 Lift out ice strainer ramp ...
Page 50: ...42 Part Number STH044 10 13 11 Turn ice wiper counterclockwise to remove ...
Page 56: ...48 Part Number STH044 10 13 19 Remove ice dispensing wheel by lifting straight out ...
Page 57: ...Part Number STH044 10 13 49 20 Water Reservoir Cover Removal A Push up on cover to snap off ...
Page 62: ...54 Part Number STH044 10 13 This Page Intentionally Left Blank ...
Page 110: ...102 Part Number STH044 10 13 This Page Intentionally Left Blank ...
Page 116: ...108 Part Number STH044 10 13 This Page Intentionally Left Blank ...
Page 122: ...114 Part Number STH044 10 13 This Page Intentionally Left Blank ...
Page 123: ......