Part Number STH038 5/12
105
2. Extremely Thin at Evaporator Outlet
There is no ice, or a considerable lack of ice formation,
at the outlet of the evaporator.
Examples: No ice at all on the outlet half of the
evaporator, but ice forms on the inlet half of the
evaporator. Or, the ice at the outlet of the evaporator
reaches 3 mm. to initiate a harvest, but the inlet of the
evaporator already has 12 mm to 24 mm of ice
formation.
3. Extremely Thin at Evaporator Inlet
There is no ice, or a considerable lack of ice formation
at the inlet of the evaporator. Examples: The ice at the
outlet of the evaporator reaches 3 mm to initiate a
harvest, but there is no ice formation at all on the inlet
of the evaporator.
4. No Ice Formation
The ice machine operates for an extended period, but
there is no ice formation at all on the evaporator.
Evaporator Tubing Routing
Routing of the tubing on the back of the evaporator
determines the ice fill pattern failure mode. The
evaporator outlet tubing does not exit directly at the
top of the evaporator, but exits several centimeters
below the top of the evaporator. Extremely Thin at the
Evaporator Outlet will first be visible several
centimeters below the top of the evaporator. Extremely
Thin at Evaporator Inlet will first be visible at the
bottom of the evaporator.
Outlet
Inlet
Thin at Outlet
Thin at Inlet
ICE
ICE
Summary of Contents for I0320A
Page 20: ...18 Part Number STH038 5 12 This Page Intentionally Left Blank ...
Page 26: ...24 Part Number STH038 5 12 This Page Intentionally Left Blank ...
Page 86: ...84 Part Number STH038 5 12 This Page Intentionally Left Blank ...
Page 124: ...122 Is the evaporator dirty Dry evaporator first then check YES NO NO ...
Page 174: ...172 Part Number STH038 5 12 This Page Intentionally Left Blank ...
Page 176: ...174 Part Number STH038 5 12 I0320 Self Contained 1 Ph ...
Page 177: ...Part Number STH038 5 12 175 I0500 Self Contained 1 Ph ...
Page 180: ...178 Part Number STH038 5 12 ...
Page 181: ......