3 - 36
G - OCCASIONAL MAINTENANCE
G1 - FUEL SYSTEM
BLEED
These operations are to be carried out only in the following cases:
• A component of the fuel system replaced.
• A drained tank.
• Running out of fuel.
Ensure that the level of fuel in the tank is sufficient and bleed in the following order:
- Open the I.C. engine bonnet.
- Put the ignition on for three minutes on the lift truck, to give the lift pump time to release air from the filter.
- Switch off the ignition with the ignition key.
BLEEDING THE INJECTORS
- Remove the injectors cover 1 (fig. G1/1).
- Loosen high pressure connectors 2 (fig. G1/2) of all the injectors.
- Activate the star ter until the diesel fuel flows out free of air at high pressure connectors
2 (fig. G1/2).
Do not engage the starter motor on a continual basis for more than 30 seconds and let it
cool between unsuccessful attempts.
- Tighten the connection while the diesel fuel is flowing out (tightening torque 30 N.m).
- The I.C. engine is then ready to be star ted up.
- Turn the I.C. engine over slowly for 5 minutes immediately after bleeding the fuel feed circuit, in order to ensure that the injection
pump has been bled thoroughly.
NOTE: If the I.C. engine functions correctly for a shor t time then stops or functions irregularly, check for possible leaks in the low
pressure circuit. If in doubt, contact your dealer.
G1/2
G1/1
1
2
2
2
Summary of Contents for B-E2 Series
Page 2: ......
Page 4: ......
Page 5: ...1 1 1 OPERATING AND SAFETY INSTRUCTIONS...
Page 6: ...1 2...
Page 30: ...1 26...
Page 31: ...2 1 2 DESCRIPTION 2 DESCRIPTION...
Page 32: ...2 2...
Page 47: ...2 17...
Page 65: ...2 35...
Page 75: ...3 1 3 MAINTENANCE 3 MAINTENANCE...
Page 76: ...3 2...
Page 78: ...3 4...
Page 97: ...3 23...
Page 103: ...3 29...
Page 107: ...3 33...
Page 109: ...3 35...
Page 116: ...4 2...
Page 118: ...4 4...
Page 127: ...4 13...