V.033007
Sprint
®
2000
3. Product
Specifications
Specifications
Sprint 2000-48
Sprint 2000-60
Sprint 2000-72
Belt Width
122
cm
(48")
152 cm (60")
183 cm (72")
Burner Width
217 cm (85.5”)
248 cm (97.5”)
278 cm (109.5”)
Heat Chamber Width
160 cm (63")
191 cm (75")
221 cm (87")
Heat Chamber Length
366-610 cm (8'-20’) or more
366-610 cm (8'-20’) or more
366-610 cm (8'-20’) or more
Expansion Head
Modules
61 cm (24")
61 cm (24")
61 cm (24")
Standard Infeed /
Outfeed Length
244 cm (96")
244 cm (96")
244 cm (96")
Overall Length
732-1097 cm (24'-36’) or
more
732-1097 cm (24'-36’) or
more
732-1097 cm (24'-36’) or
more
Exhaust Blower
System
2, 3
30 cm (12"): 50 970 l/min
(1800 cfm) @ 6 mm (1/4")
3
30 cm (12"): 50 970 l/min
(1800 cfm) @ 6 mm (1/4")
3
30 cm (12"): 50 970 l/min
(1800 cfm) @ 6 mm (1/4")
3
Gas Input Size
2.54 cm (1")
2.54 cm (1")
2.54 cm (1")
LP/Natural Gas Input
Pressure
.93-1.49 mm Hg (5"-8” w.c.)
.93-1.49 mm Hg (5"-8” w.c.)
.93-1.49 mm Hg (5"-8” w.c.)
Burner Input Maximum
4
300 000 Btu
300 000 Btu
300 000 Btu
Electrical
Requirements
1
208/230V, 3 ph, 22/21 A,
50/60 Hz, 5.3 kW
208/230V, 3 ph, 22/21 A,
50/60 Hz, 5.3 kW
208/230V, 3 ph, 22/21 A,
50/60 Hz, 5.3 kW
400V, 3 ph, 16 A, 50 Hz, 5.3
kW
400V, 3 ph, 16 A, 50 Hz, 5.3
kW
400V, 3 ph, 16 A, 50 Hz, 5.3
kW
61 cm (24”) Optional
Radiant Section
1
208/230V, 3 ph, 22/21 A,
50/60 Hz, 5.3 kW
208/230V, 3 ph, 22/21 A,
50/60 Hz, 5.3 kW
208/230V, 3 ph, 22/21 A,
50/60 Hz, 5.3 kW
400 V, 3 ph, 16 A, 50 Hz, 5.3
kW
400 V, 3 ph, 16 A, 50 Hz, 5.3
kW
400 V, 3 ph, 16 A, 50 Hz, 5.3
kW
Shipping Weight
5
1678 kg (3700 lb)
1860 kg (4100 lb)
2177 kg (4800 lb)
1
If incoming voltage differs from the voltage(s) listed in this brochure, calculate amperage
accordingly. Other electrical configurations are available: Contact M&R for details
2
Measured at the Exhaust Discharge Port
3
Static pressure
4
Normal usage varies, but is significantly lower than the stated maximum
5
Weight applies to models with a 244 cm (96”) heat/expansion chamber
Exhaust Ducts
IMPORTANT:
Check with your local heating/ventilation Contractor to be sure that exhaust ducts will
meet local building/fire codes and regulations before installation. M&R Printing Equipment does not
specify or recommend materials for the exhaust ducting of this equipment.
IMPORTANT:
Do not join the Exhaust Hood ducts with the Main Exhaust duct. This will cause
airflow restrictions and the dryer will not perform properly.