Problem
Probable Causes
Solution
The high temperature switch
mounted on the inside of the
reflector assembly has opened
up. This is due to excessive
heat at the reflector surface.
Check the operation of the blower, replaced as required.
The flash cure has
shut down and the
audible signal is
sounding. The Digital
Controller displays
the alarm message
AL-1
.
Excessive dirt, lint or dust
clogging up the blower fan
blades.
Check the fan blades and clean as necessary.
The flash cure has
shut down and the
audible signal is
sounding. The Digital
Controller displays
the alarm message
AL-2.
The infrared sensor mounted to
the center of the quartz lamp
reflector has failed.
Check the sensor and clean, adjust or replace as
required.