Cayenne
™
Series
V.121806
Set
Temperature
From the
Setup
menu, press the
F2
key to change the
temperature display from Fahrenheit to Celsius. The
control displays
F-C
on the upper line and the currently
selected temperature unit on the lower line. Press the
arrow keys to change the indication.
Set Flash Unit
Number (Z-
Series Press
Only)
IMPORTANT:
Multiple flash cure systems use a number (1-
8) in order for the PLC to determine the location of the print
station. Once the unit number has been selected, mark the
selected unit number on the flash cure for future reference.
From the
Setup
menu, press the
F4
key until
UNIT
is
displayed on the upper line and the current unit number on
the lower line. To change the unit number, press the arrow
up or down keys until the required number is displayed on
the lower line.
To exit the
Setup
menu, press the
ENT
key, or wait 10
seconds and the control exits the
Setup
menu
automatically.
6. Scheduled
Maintenance
Benefits
Properly maintained equipment operates more efficiently, reduces operating costs, and lasts longer.
A properly managed preventive maintenance program can minimize downtime, allowing you to be
your most productive.
Preparation
An effective preventive maintenance program includes:
•
proper selection, handling, and application of lubricants
•
stocking high-quality replacement parts
•
general cleaning and appearance of equipment
•
creation of a preventive maintenance history for each piece of equipment
Preventive maintenance documentation can be an invaluable resource.
WARNING:
Always disconnect the electrical power from the equipment before beginning
maintenance procedures. Lock out the electrical power source and tag the disconnect switch so
others are aware of maintenance being performed on the equipment.
24
M&R Companies 1N 372 Main St. Glen Ellyn, IL 60137 USA
Tel: +630-858-6101 Fax: +630-858-6134
www.mrprint.com