Cayenne
™
Series
V.121806
4.4.2 Z-Series
Press
Ensure the digital controller on the quartz flash is set for
PLC
control and the
communications protocol is set to
YES
.
Step 1
Connect the male plug (1) from the first flash cure
to the female receptacle (2) on the press.
Step 2
To connect multiple flash cure systems together,
connect the male plug (3) on the second flash cure
to the female receptacle (4) from the first flash
cure.
Step 3
For additional flash cures connect the male plug
(5) on the third flash cure to the female receptacle
(6) on the second flash cure.
Connect additional flash cures in the same
manner.
Step 4
Press
F4
key three times to select the
communications protocol. The control displays
MDBUS
on the upper line, and either
YES
or
NO
on the lower line indicating if the protocol is
currently selected. Press the arrow keys to
change the protocol.
Note: When
YES
is selected, the flash cure is
controlled from the main control panel.