V.
121806
Cayenne
™
Series
F1
Temperature
Press
F1
to set the temperature. The minimum
temperature setting is 32 degrees F. and the maximum is
450 degrees F.
Press the arrow up (increase) and arrow down (decrease)
keys to change the temperature setting.
Note: When the control returns to standby mode, the current
Process Temperature Value (PV) and Set Temperature
Value (SV) display.
F2
Time
Press
F2
to set the flash exposure time. The minimum
flash time is 0.5 seconds and the maximum is 10 seconds.
The current flash time displays on the lower line.
Press the arrow up (increase) and arrow down (decrease)
keys to change the flash time.
Note: The flash time on the digital controller must be set for the
maximum of 10 seconds when operating in the PLC mode
to prevent a conflict between the flash cure time and the
flash time as set on the press.
F3
Section
The quartz heating elements are arranged in three sections:
OUTSIDE
(O),
CENTER
(C) and
INSIDE
(I). Press
F3
to
select lamp sections for curing operation; the control
displays
SECT
on the top line, and
O C I
on the lower line.
O C I
displayed indicates that all three sections are
operating.
To deselect a section, press
F3
until the section letter
flashes. Press the arrow down key; the indication changes
to a dash “-“ and the section is now inoperative.
M&R Companies 1N 372 Main St. Glen Ellyn, IL 60137 USA 21
Tel: +630-858-6101 Fax: +630-858-6134
www.mrprint.com