Ref.: WB-VL-SM Ver.1 3.doc
40
5.4.
DISPLAY UNIT
1.
Remove the Monitor power cord and HDMI cable from the Monitor.
Fig. 88
2.
Detach the Monitor from Monitor column plate.
3.
Replace the Monitor with new one and fix it.
4.
Restore the Monitor power cord & HDMI cable connections
5.
Power up the Balancer and ensure the Monitor functions.
5.5.
DISTANCE / DIAMETER / WIDTH MEASUREMENT MECHANISM
5.5.1.
DISTANCE MEASURING ROD
1.
Remove the DMR Lever after removing the circlip with circlip plier.
2.
Remove the DMR assembly from cabinet after removing the two allen
screws.
3.
Replace the new DMR assembly.
4.
Do not tighte the screws fully. First ensure free movement of rod. Align
the assembly properly to have a free movement and then tighten the two
screws.
5.
Re-fIx the DMR lever.
6.
Go to Distance test option and check the function.
Fig. 89
5.5.2.
E-DISTANCE ENCODER BOARD
(For Wheel rim Distance measurement)
1.
Disconnect the 10Pin FRC cable from E-Distance encoder board and
then remove the board from DMR fixing plate.
Basic model
Premium model
Fig. 90
2.
Fixing the new E-Distance encoder board with DMR plate & move the
rod to Home position. Now align the Rectangular segment properly with
Encoder sensors by ensuring the Home encoder & other two Encoders
(Dist-A and Dist-B) are closing the first three segment teeth. If not, adjust
the plate using slotted hole. Then, ensure free movement of the Rod.
Also ensure that the Rectangular segment is aligned with the center of
Encoder and a minimum gap is maintained at the bottom.
Summary of Contents for LX WB-VL-65 DSP
Page 48: ...Ref WB VL SM Ver 1 3 doc 45 7 DIAGRAMS 7 1 BLOCK DIAGRAM 7 1 1 LCV MODELS Fig 99...
Page 49: ...Ref WB VL SM Ver 1 3 doc 46 7 1 2 HCV MODEL THREE PHASE OPERATION Fig 100...
Page 50: ...Ref WB VL SM Ver 1 3 doc 47 SINGLE PHASE OPERATION Fig 101...
Page 51: ...Ref WB VL SM Ver 1 3 doc 48 7 2 WIRING DIAGRAM 7 2 1 LCV MODELS Fig 102 1 of 3...
Page 52: ...Ref WB VL SM Ver 1 3 doc 49 Fig 102 2 of 3...
Page 53: ...Ref WB VL SM Ver 1 3 doc 50 Fig 102 3 of 3...
Page 54: ...Ref WB VL SM Ver 1 3 doc 51 7 2 2 HCV MODEL THREE PHASE OPERATION Fig 103 1 of 3...
Page 55: ...Ref WB VL SM Ver 1 3 doc 52 Fig 103 2 of 3...
Page 56: ...Ref WB VL SM Ver 1 3 doc 53 SINGLE PHASE OPERATION Fig 103 3 of 3...