Ref.: WB-VL-SM Ver.1 3.doc
31
3.
Switch ON the Balancer and conduct Self Test program as explained in
Chapter 4.6 without any errors.
LCV model
HCV 3Phase model
HCV 1Phase model
Fig. 62
5.1.3.
SBC BOARD
1.
Remove the Cooling fan assembly mounted over the SBC board.
2.
Disconnect the Power I/P (Micro USB), Video O/P (HDMI), DSP board
(40Pin FRC) connectors & Micro SDHC card.
Fig. 63
3.
Remove the fasteners and replace the defective board with New one
and restore the connectors (refer Wiring diagram - Chapter 7.2). Ensure
the 40Pin FRC is connected correctly with reference to Pin1.
4.
Load the Micro SDHC card.
5.
Re-fix the Cooling fan assy over the SBC board.
6.
Switch on the Balancer and run the Balancing program to ensure the
functions are working properly without any errors.
5.1.4.
MEMORY CARD
(with Balancing program)
1.
Remove the defective Micro SHDC card from SBC board and insert the
new card (Programmed) in to the slot.
2.
Switch on the Balancer and run the Balancing program to ensure the
functions are working properly without any errors.
Power
I/P
HDMI
Micro SDHC
at Solder side
Summary of Contents for LX WB-VL-65 DSP
Page 48: ...Ref WB VL SM Ver 1 3 doc 45 7 DIAGRAMS 7 1 BLOCK DIAGRAM 7 1 1 LCV MODELS Fig 99...
Page 49: ...Ref WB VL SM Ver 1 3 doc 46 7 1 2 HCV MODEL THREE PHASE OPERATION Fig 100...
Page 50: ...Ref WB VL SM Ver 1 3 doc 47 SINGLE PHASE OPERATION Fig 101...
Page 51: ...Ref WB VL SM Ver 1 3 doc 48 7 2 WIRING DIAGRAM 7 2 1 LCV MODELS Fig 102 1 of 3...
Page 52: ...Ref WB VL SM Ver 1 3 doc 49 Fig 102 2 of 3...
Page 53: ...Ref WB VL SM Ver 1 3 doc 50 Fig 102 3 of 3...
Page 54: ...Ref WB VL SM Ver 1 3 doc 51 7 2 2 HCV MODEL THREE PHASE OPERATION Fig 103 1 of 3...
Page 55: ...Ref WB VL SM Ver 1 3 doc 52 Fig 103 2 of 3...
Page 56: ...Ref WB VL SM Ver 1 3 doc 53 SINGLE PHASE OPERATION Fig 103 3 of 3...