Ref.: WB-VL-SM Ver.1 3.doc
21
DO NOT disturb the Wheel position until Outer calibration is
performed
Press
key twice to perform Outer calibration. The added weight will be
displayed in the Outer plane window and the Inner plane window will be zero.
The system will proceed to perform Inner calibration.
Remove the Calibration weight from the Outer plane & fix it on the Inner plane
of the wheel directly opposite as shown below:
Fig. 36
Press
key twice to perform Inner calibration. The added weight will be
displayed in the Inner plane window and the Outer plan window will be zero.
Fig. 37
Once Inner calibration is performed, press
key to save the Weight
calibration values. Saving process will happen with message prompts for few
seconds and system will go back to
WEIGHT CALIBRATION
screen.
During Outer or Inner calibration
, if “Calibration weight signal is too
high. Press
Key to proceed, or any other key to exit” error
message appears, check whether the correct calibration weight is
added on the appropriate plane or weight is not added in the Outer
plane or not shifted to Inner plane. If the weight is correct, and still
you got this error, press ENTER key and proceed with the calibration
If any error is indicated after adding weight in any of the Plane, redo
the Weight calibration
Remove the Calibration wheel and go the
POSITION TRACKING
screen. Run
the Empty shaft and zero is displayed in both the planes.
Now Balance a Wheel as explained in Chapter 7.4 of Operating manual and
then add a known weight and ensure the weight added & its positions are
displayed in the respective windows correctly.
Summary of Contents for LX WB-VL-65 DSP
Page 48: ...Ref WB VL SM Ver 1 3 doc 45 7 DIAGRAMS 7 1 BLOCK DIAGRAM 7 1 1 LCV MODELS Fig 99...
Page 49: ...Ref WB VL SM Ver 1 3 doc 46 7 1 2 HCV MODEL THREE PHASE OPERATION Fig 100...
Page 50: ...Ref WB VL SM Ver 1 3 doc 47 SINGLE PHASE OPERATION Fig 101...
Page 51: ...Ref WB VL SM Ver 1 3 doc 48 7 2 WIRING DIAGRAM 7 2 1 LCV MODELS Fig 102 1 of 3...
Page 52: ...Ref WB VL SM Ver 1 3 doc 49 Fig 102 2 of 3...
Page 53: ...Ref WB VL SM Ver 1 3 doc 50 Fig 102 3 of 3...
Page 54: ...Ref WB VL SM Ver 1 3 doc 51 7 2 2 HCV MODEL THREE PHASE OPERATION Fig 103 1 of 3...
Page 55: ...Ref WB VL SM Ver 1 3 doc 52 Fig 103 2 of 3...
Page 56: ...Ref WB VL SM Ver 1 3 doc 53 SINGLE PHASE OPERATION Fig 103 3 of 3...