Ref.: WB-VL-SM Ver.1 3.doc
39
Fig. 85
5.3.
MECHANICAL BRAKE
(NA for SR Rev.R50/above & HCV models)
5.3.1.
LIMIT SWITCH
1.
Remove the Limit switch clamp and disconnect the cables from Motor
control board.
Fig. 86
2.
Remove the Limit switch from clamp and fix new Limit switch with
correct direction.
3.
Fix the Limit switch clamp to cabinet & connect 2Pin SR cable with
Motor control board at appropriate place by ensuring the Limit switch is
in activated position.
4.
Apply the Brake pedal manually & release it to check the functions.
5.
Switch ON the Balancer & ensure that the motor is running without any
problem.
5.3.2.
MANUAL BRAKE
1.
Remove the Brake shoe rod (bent rod with brake shoes).
2.
Remove the Brake vertical rod.
3.
Remove Brake pedal.
4.
Remove Brake lever from bottom side of cabinet.
a.
And take out the lever.
5.
Replace the new brake lever and fix the nut.
6.
Fix the pedal.
7.
Fix the Brake shoe rod.
8.
Maintain a gap of 1mm between shoe and driven pulley and then tighten
the bolts in the U clamp at back of cabinet.
Fig. 87
Summary of Contents for LX WB-VL-65 DSP
Page 48: ...Ref WB VL SM Ver 1 3 doc 45 7 DIAGRAMS 7 1 BLOCK DIAGRAM 7 1 1 LCV MODELS Fig 99...
Page 49: ...Ref WB VL SM Ver 1 3 doc 46 7 1 2 HCV MODEL THREE PHASE OPERATION Fig 100...
Page 50: ...Ref WB VL SM Ver 1 3 doc 47 SINGLE PHASE OPERATION Fig 101...
Page 51: ...Ref WB VL SM Ver 1 3 doc 48 7 2 WIRING DIAGRAM 7 2 1 LCV MODELS Fig 102 1 of 3...
Page 52: ...Ref WB VL SM Ver 1 3 doc 49 Fig 102 2 of 3...
Page 53: ...Ref WB VL SM Ver 1 3 doc 50 Fig 102 3 of 3...
Page 54: ...Ref WB VL SM Ver 1 3 doc 51 7 2 2 HCV MODEL THREE PHASE OPERATION Fig 103 1 of 3...
Page 55: ...Ref WB VL SM Ver 1 3 doc 52 Fig 103 2 of 3...
Page 56: ...Ref WB VL SM Ver 1 3 doc 53 SINGLE PHASE OPERATION Fig 103 3 of 3...