Ref.: WB-VL-SM Ver.1 3.doc
34
4.
Remove the Rotor fixing bolt and detach the Rotor assembly from cabinet.
Fig. 70
5.
Fixing the new Rotor assembly with Cabinet & fasten it firmly.
Fig. 71
6.
Fixing the SB Screw rod with the Rotor & tighten it firmly with nut. Before
fastening the Sensor nut, ensure the SA & SB screw rods are centered in the
slotted hole in Cabinet:
Fig. 72
7.
Fix the Driven pulley with Main shaft and then put the Belt between Driven &
Motor pulleys.
Fig. 73
8.
Fix the Revolution Index encoder board with Rotor firmly.
9.
Fix the MCD with Main shaft.
Fig. 74
10. Switch on Balancer and calibrate it as explained in Operating manual.
11. Run the Balancing program and ensure the functions are working properly
without any errors.