Ref.: WB-VL-SM Ver.1 3.doc
16
SPINDLE ZERO
By default,
LOW POINT
will be highlighted. Press
key to proceed with
Low
point
calibration.
Fig. 25
Remove Wheel, Wheel seating cone & QCLN from shaft if already mounted.
Press
key twice to run the Empty shaft. SA & SB Sensor values will be
displayed (in millivolts) in the respective window (limit: 30mV) including RPM
and the system will go to
RIM PARAMETERS
screen.
Fig. 26
Mount the wheel.
For Low point
– use a fairly balanced wheel with Rim dia of
12”-16”. Unbalance should be 30gm min.
For High point
– use a fairly balanced wheel with Rim dia
>16”. Unbalance should be 50gm min.
For Single point
– use a fairly balanced wheel with Rim dia 12”-
16
”. Unbalance should be 30gm min.
Use
/
keys to move to next parameters.
Two point calibration (Low Point & High point) is recommended for
better accuracy of Unbalance weight for all range of wheels. In case of
non-availability of two sizes of wheels, proceed with Single point
calibration
If Auto Dia / Width are enabled & calibrated already, ensure the
acquired values are displayed correctly. Else, set Dia & Width values
manually as explained above
If empty shaft unbalance is more,
“Spindle unbalance is beyond limits
for calibration
” error message will be displayed. Stop Calibration and
call Authorised Service personnel
DO NOT use Wheel with Re-treaded tyre or Wheel with more runout
for calibration
Summary of Contents for LX WB-VL-65 DSP
Page 48: ...Ref WB VL SM Ver 1 3 doc 45 7 DIAGRAMS 7 1 BLOCK DIAGRAM 7 1 1 LCV MODELS Fig 99...
Page 49: ...Ref WB VL SM Ver 1 3 doc 46 7 1 2 HCV MODEL THREE PHASE OPERATION Fig 100...
Page 50: ...Ref WB VL SM Ver 1 3 doc 47 SINGLE PHASE OPERATION Fig 101...
Page 51: ...Ref WB VL SM Ver 1 3 doc 48 7 2 WIRING DIAGRAM 7 2 1 LCV MODELS Fig 102 1 of 3...
Page 52: ...Ref WB VL SM Ver 1 3 doc 49 Fig 102 2 of 3...
Page 53: ...Ref WB VL SM Ver 1 3 doc 50 Fig 102 3 of 3...
Page 54: ...Ref WB VL SM Ver 1 3 doc 51 7 2 2 HCV MODEL THREE PHASE OPERATION Fig 103 1 of 3...
Page 55: ...Ref WB VL SM Ver 1 3 doc 52 Fig 103 2 of 3...
Page 56: ...Ref WB VL SM Ver 1 3 doc 53 SINGLE PHASE OPERATION Fig 103 3 of 3...