GB

• Checking the rated thermic capacity 

The rated thermic capacity must be checked by an authori-

zed technician or by the gas supplier Institution, by following 

the instructions mentioned in the present manual. This che-

cking operation must be carried out in case of conversion or 

adaptation to another type of gas and during each mainte-

nance operation. The rated thermic capacity as well as the 

connection pressures has to be up to the ones quoted on the 

technical data table. The sealed parts mustn’t ever be ma-

nipulated.

• Volumetric system

You can get the foreseen rated thermic capacity by using the 

proper  injectors  to  the  connection  pressure  in  conformity 

with the type of gas. The thermic capacity check is carried 

out through a meter and a chronometer. The right gas vo-

lume that has to pass per unities of time can be read on the 

technical data tables. Such a value for the connection has to 

be kept inside the foreseen range with a tolerance of about 

5%. In case the operator notices some deviations, he should 

check that the used injectors have the correct diameter.

• Checking the connection pressure 

Before starting the oven, we recommend checking, in the 

plates mentioning the characteristics and in the supplemen-

tary one, if the oven is preset for the type of gas or the gas 

family present in loco. The connection pressure is measured, 

when the oven is working, using a pressure gauge for liquids 

like a “U” shaped manometer (minimum solution 0.1mbar). 

To  perform  this  check,  unscrew  the 

screw 3 and connect the manometer 

to the inlet tube pressure of the valve 

(pos.3).

- adjust the pressure if necessary.

- Remove the pressure reducing valve 

and screw down the screw n.3 

3 – Inlet pressure tube 

4 – Outlet pressure tube 

6 -  Pressure regulator of the modula-

ting device

• Kontrolle der Nennwärmebelastung

Die Nennwärmebelastung muss von dem beifugten Tech-

niker oder vom Gasversorgungsamt laut Informationen In 

diesem Handbuch kontrolliert werden. Solche  Überprü-

fung muss bei Umstellung oder Anpassung an eine ande-

re Gasart  und bei allen Wartungseingriffen erfolgen. Die 

Nennwärnebelastung sowie die  Anschlußdrücke  müssen 

den in der Tabelle der technischen Werten entsprechen. 

Die  versiegelten Teile  dürfen  niemals  manipuliert  wer-

den.

• Volumetriche Methode

Die  vorgesehene  Nennwärmebelastung  erziehlt  man  durch 

Benutzung  von  den  angemessenen  Injektoren  bei  der    An-

schlußdruck gemäß der Gasart. Die Kontrolle der Wärme- Be-

lastung wird durch einen Zähler oder ein Chronometer ausge-

führt. Die genaue Gasmenge pro Zeiteinheit ist den Tabellen 

der technischen Daten zu entnehmen . Solcher Anschlußwert 

ist mit einer Toleranz von ± 5% zu halten. Sollte man Abwei-

chungen feststellen, muss  man sicherstellen, dass Injektoren 

mit richtigen Durchmesser benutzt worden sind.

• Kontrolle des Anschlußdrucks

 

Vor der Inbetriebnahme des Gerätes muss man feststellen, 

ob der Apparat für die vorhandene Gasart geeignet ist. 

Daher ist es notwendig, das Eigenschaftsschild sowie das 

Zusatzschild zu überprüfen. Der Anschlußdruck wird bei 

funktionierendem Apparat mittels eines Druckmessers für 

Flüssigkeiten wie einem “ U”- Manometer (Mindesauflö-

sung 0.1 mbar) gemessen werden. 

Um diese Kontrolle auszuführen,  

muss man Schraube 3 herausschrau-

ben und den Druckmesser an die 

Druckmesserkupplung im Eingang 3 

des Ventils anschließen.

- Druck einstellen, falls erforderlich.

- Druckminderer entfernen und

Schraube 3 einschrauben

3 – Druckmesserkupplung am Eingang

4 - Druckmesserkupplung am Ausgang

6 – Druckregler des Modulators

Summary of Contents for MFE100

Page 1: ...za Gasovensforpizza Modelle Type MFE80 MFE100 MFE110 MFT120 MFT140 MFT160 MFE140 MFE170 MFR115 RC115 MFRC125 MFR135 MFRC135 WARTUNGS UND GEBRAUCHSANWEISUNGEN INSTRUCTIONS FOR THE USE AND MAINTENANCE V...

Page 2: ...dex 1 GENERAL INFORMATION 1 1 SYMBOLS USED INTHE MANUAL 1 2 TERMS 2 SAFETY RULES 3 PRESENTATION 3 1 GENERALITY 3 1 2 MAIN COMPONENTS 3 2 CAUTIONS 3 3 NOT ALLOWED USES 3 4 MACHINE IDENTIFICATION DATA 4...

Page 3: ...ND STELLUNGENVON FEN MIT FACKELROHR ANLAGE 2 VERPACKUNGSSCHILD 11 ERSTES ANFEUERN 12 INSTALLATION DES BRENNERS 7 5 gas connection 7 6 conversionto othertypes of gas 8 use 8 1 starting 8 2 oven use 8 2...

Page 4: ...r andere Zwecke als die verwendetwerden diemitdemBenutzervorausgesehen sind Dieses Handbuch wurde urspr nglich in Italienisch verfasst M A M snc via C Angiolieri 28 34 41100 Modena Italy Tel 39 059 3...

Page 5: ...fiedtechnician Itindicatestheinstallation maintenanceorregulation proceduresthatmustbestrictlycarriedoutbypersonnel ofthemanufacturercompany oftheServicingCentre or by qualified technicians 1 1 Symbol...

Page 6: ...m Personal durchgef hrt werden Die von dem Konstrukteur oder von dessen Agenten versiegeltenTeile d rfen nicht von dem Installateur oder Benutzer reguliert werden SAFETY RULES Read this manual careful...

Page 7: ...2 HAUPTBAUELEMENTE A vorgefertigter Ofen B ausger stetes Zubeh r B1 Schaufel B2 kleine Schaufel B3 Schrubber B4 Fallt r Presentation 3 1 GENERALITY The M A M oven is a prefabricated gas oven It s mad...

Page 8: ...3 4 IDENTIFIZIERUNGSDATEN DieIdentifizierungsdatensindaufdemdaf rvorgesehenen Identifizierungsschildeingetragen dassopositioniertist wie im Bild des Kapitels TECHNISCHE DATEN UND MA E angegeben ist 3...

Page 9: ...and the oven gas prearrangement is located under the identification data plate and inside the documentation that goes with the package at the delivery See PACKAGE PLATE enclosure 2 Technische Daten de...

Page 10: ...G20 3 60 m3 h G30 2 68 kg h G25 4 18 m3 h Elektroanschluss Electrical connection 220 230V 50 Hz W rmeleistung Thermal capacity 17 22 34 KW Wirkungsgrad derVerbrennung Burning efficiency 80 Verlust Lo...

Page 11: ...sure a good visibility from any point it mustn t createdangerousreflectionsandpermittheclearreading of the control panels as well as the individuation of the emergency buttons in the version with rota...

Page 12: ...bakingit scompulsorytheuseofthekitofaccessories see section 3 1 2 VORRICHTUNGEN UND SICHERHEITS SCH TZE DER MASCHINE DieVorrichtungenundSicherheitssch tzed rfenniemals manipuliert werden Bevor der Ap...

Page 13: ...SIDE OF THE PALLET and take it as near as possible to the installation area HEBEN TRANSPORT UND LAGERUNG F r den Transport des Ofens sind Verpackungen von verschiedenen Allgemeinheiten vorgesehen ES...

Page 14: ...HREN BEREICH zu betrachten ist SolltedieMaschinenichtinkurzerZeitinstalliertwerden istesempfehlenswert sieineinen berdachtenRaumohne Feuchtigkeit zu stellen 6 2TRANSPORTion AND HANDLING Thegasovenhast...

Page 15: ...9000 kcal Brenner ist 1015 m3 h Q 35 X kW DerOberteildesOfens wosichderRauchfangbefindet muss pr fbar bleiben InstallaTION 7 1 INSTALLATION Theinstallationoftheovenmustbecarriedoutbyqualified personne...

Page 16: ...evelonthecookingtop pictureA Carryouttheregulation bypositioningsomemetallicplaquesunderthesupporting frame feet picture B In order to have a correct oven working if it is placed outside or in another...

Page 17: ...zu vermeiden benutzen Sie nur passende Sicherungen richtiger Spannung DIE DURCHF HRUNG DES ELEKTROANSCHLUSSES MUSS MIT SPANNUNGSFREIER SPEISELEITUNG ERFOLGEN 7 3 ELECTRICAL CONNECTION ALL THE ELECTRI...

Page 18: ...nk installation the oven must be included in a unipotential system connecting it to the other equipments with a conductor cable not shorter than 10 mm2 by means of a clamp countermarked by the followi...

Page 19: ...direkt nach Au en ablassen Bild A Wenn die Verbrennungsgase durch erzwunge nen Zug abgelassen werden mussdieGaszuf hrung andieGer tedirektvondemer zwungenen Zug abh ngen und muss sich unterbrechen we...

Page 20: ...gen geblasen werden die mit einem sehr wirksamenRauchfangverbundenoderdirektdrinnensind Rauchfanganschluss einzelne Haube vom Ofen bis aufs Dach bei Einhaltung der geltendenVorschriften ber Rauchf nge...

Page 21: ...o connect at least three of them in series and keep them open DIEINSTALLATIONDESRAUCHABZUGSMUSSVONQUA LIFIZIERTENFACHLEUTENDURCHGEF HRT WERDEN DIE EIN INSTALLATIONSZERTIFIKAT AUSSTELLEN K NNEN 7 5 GAS...

Page 22: ...educing valve andscrewdownthescrewn 3 3 Inletpressuretube 4 Outletpressuretube 6 Pressure regulator of the modula tingdevice Kontrolle der Nennw rmebelastung DieNennw rmebelastungmussvondembeifugtenTe...

Page 23: ...gungskreisesweiter 7 6 CONVERSION TO OTHER TYPES OF GAS Iftheovenisn tpre settothegas availableinyourgasinstallation it s compulsory to carry out the conversion to another type of gas This adaptation...

Page 24: ...gas self both when the burner is off and when it s on Give tension to the burner and place the switch or the thermostat in 1st flame then through the cock as per photo 1 calibrate the desired quantit...

Page 25: ...Erreichung der eingestelltenTemperatur die mittels den Tasten programmierbar ist Im AUTOMATISCHEN Betrieb erscheint am Multifunktionsdisplay die Aufschrift AUTO Durch Dr cken der Tasten wird die Betri...

Page 26: ...ert dieTaste die gegenw rtige Zeit oben rechts am Display DISPLAY WERT SENKEN DurchDr ckenderTastewirdderaufdemDisplayvisualisierteWertgesenkt dervondervorheraktivierterFunktionbestimmt wordenist DieT...

Page 27: ...activated both in automatic and in manual condition R RESET OFTHE BURNER BLOCK This push button is used to unblock the burner in case the flame does not light on INPUT OF PROGRAMMED AUTOMATIC STARTING...

Page 28: ...locken istdieTemperatursondekurzgeschlossen 1 2 ist die Sonde unterbrochen berpr fen Sie dass der Verbindungsstecker nicht abgeh ngt ist Auswechslung der Sonde 1 die Gesteinsfaser von ber dem Ofen nac...

Page 29: ...pparatsverwendenSieaufkeinenFall Wasserdr ck oder Dampfstrahlger te Stauben Sie periodisch den Brenner durch Druckluft ab Siehe Abbildung 7 6 Zone H blasen MaINTENANCE 9 1 SAFETY CONDITIONS DURINGTHE...

Page 30: ...ung nicht komplett geschlossen sind Sollte man Betriebsst rungen feststellen k nnteSchmutz Ru Mehl Pizzateigusw aufdieInnen seitederdenBrennersch tzendenEdelstahlkegelgefallen sein Um ihn zu reinigen...

Page 31: ...getrennt werden sp ter ist die Entsorgung bei AUTORISIERTEN MTERN in bereinstimmung mit den geltenden M llnormen durchzuf hren DISASSEMBLY ELIMINATION 10 1 DISASSEMBLY Whentheovenisnolongerexploitabl...

Page 32: ...AGE 2 VERPACKUNGSSCHILD ENCLOSURE 2 PACKAGE PLATE Technische Daten und Abbildungen sind ungef hr und nicht verbindlich Die Firma beh lt sich das Recht vor jederzeit alle nderungen vorzunehmen die sie...

Page 33: ...32 www mamforni it D GB AUSSENMASS external dimensions Aussenmass Dimensions UM cm A B C D E F G 115 180 175 195 120 112 94 134 135 195 190 200 120 133 109 149...

Page 34: ...ww mamforni it D GB STELLUNG DES FACKELROHRS torch burner position Seitenansicht Lateral view stirnseitige Ansicht A Brenner B Z ndkerze C Kerze Erhebung Frontal view A Burner B Ignite plug C Survey p...

Page 35: ...34 www mamforni it D GB VERPACKUNGSSCHILD package plate...

Page 36: ...n PROBLEML SUNG Siehe Seite 29 Punkt 9 4 Periodische Reinigung mit Druckluft blasen Siehe Abbildung 7 6 Zone H blasen FIRST STARTING Check if gas is connected and electrical current is on IN PHASE Sta...

Page 37: ...1 Den Brenner in das geeignete Loch stecken und am B gel befestigen Put the burner into the proper hole and fix the clamp 2 3 Den Konsolentr ger B gel befestigen Fix the console carrier clamp 4 Die Ko...

Page 38: ...n Connecttheplugtotheprobe 6 Die zwei Stecker des Brenners einstecken Connect the two plugs of the burner 7 Gashahn anschlie en Connect the gas 8 220Volt Strom phasengleich anschlie en Connect the 220...

Page 39: ...NOTE...

Page 40: ...NOTE...

Page 41: ...NOTE...

Page 42: ...M A M snc via C Angiolieri 28 34 41123 Modena Italy Tel 39 059 330219 39 059 330189 Fax 39 059 334521 www mamforni it mam mamforni it studiolibra it formigine...

Reviews: