23
M5 – Eco
CE
If the pump motor does not rotate, check the electrical
connections and the position of the main switch in the
electrical box. If the pump still does not rotate even with all the
electrical connections correct and the main switch on,
do not
open the electrical box but leave the machine to be examined
by an authorised technician or a qualified electrician.
The water plant can be connected to joint
(A)
of the
mixing chamber after having checked the correct
direction of rotation of the machine.
Attention!
In the case of rapid binding materials
(with many additives) the water hose will
be connected to the
(B)
joint of the
mixing chamber.
Air connection
Air connection
(1)
on the machine provides a
possible cleaning pistol.
Check the compatibility of the attachments to
the hose and the machine before connecting
the hose. Unsuitable connections must be
replaced by suitable connections.
The supplied manometer
(2)
adjusts the
compressor and is preset by the factory.
Compressor
There is an on/off switch
(3)
on the compressor.
Since the compressor is controlled by the
manometer the switch must be „On“ to be able
to use it.
The compressor can be turned off thanks to this
switch if there are electrical or maintenance
problems.
Adjusting the quantity of water
Pressure flow indicator
Pressure flow adjustor
It is possible to adjust the desired flow of water pressure with the pressure
flow adjustor.
The first adjustment acts as a rough calibration. Thanks to successive micro-
adjustments it is possible to adjust the machine perfectly, depending upon
the composition of the desired material. Take the instructions of the
manufacturer of dry materials into consideration during the adjustment of
the values.
1
2
3
ATTENTION
B
A
ATTENTION