34
M5 – Eco
CE
S
OL VING PROBLEMS
Attention!
The machine must be turned off, disconnecting the power by
removing the plug from the socket, before any intervention
(cleaning, maintenance, repair).
Mistakes and faults should not occur if the instructions just described are
observed carefully. For possible problems not treated in this manual call
your zone representative who will be able to provide you with all the
necessary information.
Problem
Possible cause
Solution
Check the electrical
connection
Power interrupted
Check the switches
Fault at the electrical plant
Apply to the
MALTECH
assistance
service
Check that all the taps
are open
Check that the hoses
have no bends
Water flow interrupted
Clean possibly
obstructed hoses
Water pump stopped
Apply to the
MALTECH
assistance
service
Water pressure too low
Check the water
pressure on the indicator
Clean the filter
The plant does not
start-up.
The plant stops and
does not start-up
again
Filter obstructed
Install a new filter
The plant makes
strange noises
Apply to the
MALTECH
assistance
service
Defective dry material
Fill the material
container
Only water emerges
from the sprayer
Cell disc or shaft
defective/not installed
correctly
Check by specialised
personnel
Defective pressure
reduction motor
Apply to the
MALTECH
assistance
service
Material does not
emerge from the
sprayer
Direction of rotation
incorrect
Check direction of
rotation
Material of the wrong
consistency emerges
from the sprayer
Adjust the quantity of
water
Adjust the quantity of
water on the flow
adjustor
Defective/worn rotor or
screw
Replace rotor/screw
Defective pressure reducer
Apply to the
MALTECH
assistance
service
Material of different
consistencies emerge
from the sprayer
Worn mixing shaft
Install new mixing shaft
ATTENTION
www.markham-sheffield.co.uk - Tel: +44 (0) 1909 730861