51
10/07
Specification
Desc./Quantity
Inlet:
95.0 ± 0.3 mm
Outlet:
94.2 ± 0.3 mm
Specification
Desc./Quantity
Standard clearance:
0.025 ÷ 0.052 mm
Admissible limit:
0.09 mm
Specification
Desc./Quantity
Standard clearance:
0.013 - 0.04 mm
Admissible limit:
0.08 mm
Specification
Desc./Quantity
Inlet:
4.96 mm
Outlet:
4.945 mm
Specification
Desc./Quantity
Inlet:
4.987 - 4.972 mm
Outlet:
4.975 - 4.960 mm
Inspecting the valves
- Measure the diameter of the valve stems in the three positions indicated in the
diagram.
- Calculate the clearance between valve
and valve guide.
- Check the deviation of the valve stem by
resting it on a "V" shaped abutment and
measuring the extent of the deformation by
a comparator.
Characteristic
Limit values admitted:
0.01 mm
Inspecting the valve stem guide clearance
- After measuring the valve guide diameter and the valve stem diameter, check the
clearance between guide and stem.
- Check that there are no signs of wear on the surface of contact with the articulated
register terminal.
STANDARD DIAMETER
MINIMUM ADMISSIBLE DIAMETER
STANDARD VALVE LENGTH
OUTLET
INLET
- Check the concentricity of the valve head
by arranging a comparator at right angle
relative to the valve head and rotate it on a
"V" shaped abutment.
Characteristic
Admissible limit:
0.03 mm
Summary of Contents for 500 cc 4T