background image

 

30

 

11.TROUBLESHOOTING 

 
C ertain faults may ocur during normal use of the appliance: 
 

The pilot burner does not ignite 

Causes: 
● 

Electrod poorly fixed or incorrectly connected. 

● 

Electric ignition or electrode cable damaged. 

● 

Insufficient gas pressure. 

● 

Pilot injector clogged. 

● 

Gas valve faulty. 

 

The pilot burner goes out when the ignition buton is relesed. 

Causes: 
● 

Thermocouple faulty or not sufficiently heated by pilot 

burner. 
● 

Gas pressure low at valve. 

● 

Gas valve faulty. 

● 

Safety thermostat(s) tripped. 

 

The burner does not ignite when the pilor burner is lit. 

Causes: 
● 

Low pressure in gas pipes. 

● 

Injector clogged. 

● 

Gas valve faulty. 

● 

Gas outlet holes on burner clogged. 

● 

Motor thermal cut-out tripped. 

● 

Timer faulty. 

● 

Door micro-switch faulty or door not closed properly. 

● 

Operating thermostat or bulb damaged. 

 

The oven temperature control does not work. 

Causes: 
● 

Operating thermostat faulty. 

● 

Gas valve faulty. 

 

12.  LAYOUT OF MAIN COMPONENETS 

 
(All  work  inside  the  appliance  must  only  be  carried  out  by  a 
trained installer authorised by the manufacturer. 

Open  the  control  panel  and  LH  side  panel  on  the  appliance  to 
gain access to the following components: 
● Water solenoid valve. 
● Safety and operating thermostats. 
 To  replace  the  bulb  on  the  safety  thermostat,  proceed  as 
follows: 
-  remove  the  fixing  screw  on  the  cover  at  the  rear  of  the 
appliance. 
- Remove the fume exhaust pipe (if fitted). 
- Raise the back LH side of the cover. 
- Replace the thermostat bulb, taking care to correctly position 
the new bulb in its seat. 
● Pilot burner and main burner. To remove, first undo the fixing 
screws. 
Pilot burner and main burner injectors. Replacment and primary 
air adjustment. 

 
 

Note:

 

The  control  panel  may  be  opened  to  gain  accessto  all  the 
appliance’s gas and electrical components, including the power 
terminal board (also accessible externally from underneath the 
appliance) and fuse. 
To replace the gas solenoid valve, disconnect the pilot line and 
thermocouple  and  disconnect  the  gas  inlet  and  outlet 
connection. 
● The rear panel may be removed to gain accessto the electric 

motor after first removing the fan suction panel and fan. 

 
 

 

Summary of Contents for MKF-20G

Page 1: ...LUM KULLANIM VE BAKIM KILAVUZU GAS HEATED CONVECTION OVENS MKF 20G MKF 40G GN 1 1 INSTALLATION OPERATION AND MAINTENANCE MANUAL 2012 TLM 020 0041 ED NO 2 C HAZI KULLANMADAN NCE KULLANMA KILAVUZUNU MUT...

Page 2: ...ection 0 5 5 F M TR D Bo altma ya danl k P G kablosu giri i W Su ba lant s giri i 0 5 5 F M MKF 40G MKF 20G GB IE D Drain P Power supply inlet W Water supply connection 0 5 5 F M TR D Bo altma ya danl...

Page 3: ...sistemi 10 Gaz egzoz sistemi diyagram 11 4 Elektrik ba lant s 12 5 Su ana ba lant lar 12 6 Gaz ba lant s 12 7 Farkl tipte gazlar n d n m 13 8 Emniyet cihazlar 13 9 al ma testi 13 10 Servis 14 Tablo 2...

Page 4: ...cakl n g r lmesi ve ayarlanmas i in mikrostat F r n i kabin ayd nlatmas Mutfa a ve evreye daha az s da l m sa lanmas ve d k f r n d s cakl klar i in ift caml f r n kapa 2 ANA B LE ENLER Taral izgi il...

Page 5: ...5 MKF 40G 3 1 4 5 6...

Page 6: ...lant s giri i ISO 7 1 ap 1 2 M 1 2 M Nominal s giri i Kw 16 32 Gaz kategorisi II2H3B P II2H3B P Yap tipi B21 B21 Duman ekzoz sistemi fig r EK L 5 6 EK L 7 8 G20 do al gaz giri bas nc m bar 20 20 L P...

Page 7: ...l yedek par alar kullan larak yetkili servis merkezleri taraf ndan yap lmal d r Bu y k ml l e uyulmamas cihaz n g venli ini tehlikeye atar ve garantisini ge ersiz k labilir Ellerinizin yanmamas i in f...

Page 8: ...N N KORUNMASI 4 1 Paketleme Kullan lan t m ambalaj malzemeleri evre dostudur Bunlar hi bir risk te kil etmeden saklanabilir ve ya bir yakma tesisinde yak labilir Geri d n me uygun plastik malzemeler a...

Page 9: ...din Ambalaj evre korunmas ile ilgili b l mde anlat ld gibi at n z Cihaz n genel boyutlar ve ba lant lar i in bu el kitab n n ba nda bulunan kurulum emalar na bak n z Makinenin kurulum esnas nda sol ta...

Page 10: ...ferans alarak cihaz n yap t r n belirleyiniz b Kurulum yerinden egzoz gaz tahliyesi i in gereken gaz egzoz sisteminin t r n a a da g sterilen yap tipi diyagramlar ndan se iniz r davlumbaz d ar dan kan...

Page 11: ...ap rutin olarak kontrol edilmelidir Kesit daralmas ya anmamas i in kirlilik durumlar nda mutlaka temizlenmelidir nemli Tesisat ve davlumbaz i indeki filtrelerin bile enleri yan c olmayan malzemelerde...

Page 12: ...yerek d n m n ger ekle tiriniz Gaz n farkl tipte d n m Gaz ba lant s montaj a z sar renklidir Cihaz kurmadan nce tahmini t ketimi ve gaz talebinizin uyumlulu unu kontrol etmesi i in yerel gaz tedarik...

Page 13: ...ik ayg tlar ile donat lm t r Koruma sigortalar kontrol panelinin arkas na monte edilmi tir elektrik emas na bak n z De i tirmek i in kapa s k n ve yanm olan sigortayla o sigortayla ayn derecede olan b...

Page 14: ...jekt r B l m 7 2 G30 G31 L P G Propan Gaz 2 2 2 2 220 220 2 2 2 2 255 255 G20 Do al Gaz NG 3 0 3 0 300 300 3 0 3 0 300 300 Pilot yak c enjekt r B l m 7 4 G30 G31 L P G Propan Gaz n 24 n 24 n 24 n 24 G...

Page 15: ...i e itimli bir tesisat taraf ndan yap lmal d r A a daki bile enlere ula mak i in cihaz zerindeki kontrol panelini ve LH yan panelini a n z Su selenoid valfi G venlik ve i letim termostatlar Emniyet te...

Page 16: ...tutun 2 1 2 1 C HAZIN ALI TIRILMASI Su giri vanas n ve cihaz besleyen ana alteri a n z lk olarak B numaral anahtar 5 numaral pozisyona al n z E numaral g lambas yanacakt r I numaral gaz anahtar n sa a...

Page 17: ...deformasyon ezilme durumlar n kontrol edin gerekirse de i tirin Ba lant elemanlar uygun anahtar ile s k lerek difiz r yerinden kar l r ve f r n i kabinin temizlenmesi sa lan r Fan panelini tekrardan...

Page 18: ...oning 24 3 Gas exhaust system 25 Gas exhaust system diagrams 26 4 Electrical conection 27 5 Water main connections 27 6 Gas connection 27 7 Conversion to different type of gas 28 8 Safety devices 28 9...

Page 19: ...Temperature reading and configurating microstat probe only available on certain models Oven chamber lighting Double glazed oven door for reduced heat dispersion into the kitchen and low external oven...

Page 20: ...20 MKF 40G 3 1 4 5 6...

Page 21: ...ection inlet ISO 7 1 Diameter 1 2 M 1 2 M Nominal heat input Kw 16 32 Gas category II2H3B P II2H3B P Construction type B21 B21 Fume exhaust system figure Fig 5 6 Fig 7 8 G20 natural gas inlet pressure...

Page 22: ...rried out by authorised service centres using original spare parts Failure to comply with this obligation may jeopardise the safety of the appliance and invalidate the guarantee When the oven is hot o...

Page 23: ...ment CE CE marking IP Degree of protection 4 SAFEGUARDING THE ENVIRONMENT 4 1 Packaging All the packaging materials used are environmentally friemdly They may be stored at no risk or burnt at an autho...

Page 24: ...s instructed in the chapter on Safeguarding the environment Refer to the installation diagrams at the beginning of this handbook fort he appliance s overall dimensions and connections The RH side of t...

Page 25: ...g to Table 1 Technical Data or the appliance identification plate b Select the construction type diagram from those illustrated below featuring the type of gas exhaust system needed to evacuate the ex...

Page 26: ...tems Fig 1 and 5 the exhaust ducting must NOT exceed 3 metres in length OR vary in diameter and must be routinely checked and cleaned Important Make sure any extension ducting and the filters inside t...

Page 27: ...NGS Make sure the appliance corresponds with the gas supply to which it is connected If the appliance does nor correspond with the gas supply convert following the instructions given in section 7 belo...

Page 28: ...trol panel To replace unscrew the cap and replace the blown fuse with another of the same rating The correct rating is indicated on the corresponding fuse plate Oven chamber safety thermostat manual r...

Page 29: ...30 G31 L P G Propan Gas AU 2 2 2 2 220 220 2 2 2 2 255 255 G20 Natural Gas NG 3 0 3 0 300 300 3 0 3 0 300 300 Pilot burner injector Section 7 4 G30 G31 L P G Propan Gas AU n 24 n 24 n 24 n 24 G20 Natu...

Page 30: ...nce must only be carried out by a trained installer authorised by the manufacturer Open the control panel and LH side panel on the appliance to gain access to the following components Water solenoid v...

Page 31: ...the water and gas shut off valves 2 1 TURNING ON THE APPLIANCE Turn the water inlet valve and the main switch that feeds device First turn selector knob B to position 5 power led illuminates to indica...

Page 32: ...onnection cable and plug Yearly Check connection cable replace it if necessary and plug To facilitate the task of cleaning the oven remove the trolley mounted unit runners in the oven base if fitted a...

Page 33: ...33 MKF 20G MKF 40G KUMANDA PANEL CONTROL PANEL...

Reviews: