7.CONVERSION  TO  DIFFERENT  TYPE 
OF GAS   

 
 
 
 
 
 
 
 
 

7.1 

ACCESS TO COMPONENTS 

(See Figs. “7” and “8” following) 

7.2 

 REPLACEMENT OF MAIN BURNER INJECTOR 

●  To  gain  Access  to  the  main  burner  injectors,  remove  the  RH 
side panel. 
● Slacken screw 

“A”

 and undo injector 

“C”. (fig. “7”)

 

●  Remove  the  injector  “C”  with  the  one  corresponding  to  the 
type of gas supply, as indicated in 

Table 2.

 

●  The  injector  diameter  is  indicated  in  hundredths  of  a 
millimetre  on  the  injector  body  (i.e.  a3.5  mm  Ø  injector  is 
marked 350).  
● Fit the new injector “C” in aerator “B”, remount the assembly 
in its original position and tighten down the injector. 

7.3  TESTING  THE  PRIMARY  AIR  ON  THE  MAIN 
BURNER 

 

(Fig. “8”)

  

● The primary air flow rate is correct when the flame does not 
detach when the burner is cold or  backfire when the burner is 
hot. 
● To adjust the primary air flow rate, proceed as follows: 
●  Slacken  screw  “A”  and  adjust  aerator  “B”  to  distance  “H”  as 
shown in Table 2. 
● Retighten screw “A”. 

7.4 REPLACEMENT OF PILOT BURNER INJECTOR 

(Fig. “8”)

  

● Remove ignition electrode “C”. 
● Undo fitting “A” on the pilot line. 
● Remove injector “B” and replace with the one corresponding 
to the type of gas supply, as indicated in Table 2. 
● The injector identification number is stamped on the injector 
body. 
● Reconnect the pilot line with fitting “A”. 
● Remount ignition electrode “C”. 
●  The  gas  shut-off  valve  is  not  fitted  with  a  minimum 
adjustment screw. The operation of the burner is therefore ON 
or OFF. 

 
 
 

 

7.5 GAS CONVERSION PLATE 

If the appliance is converted to a different gas supply, affix the 
correct  adhesive  tag  indicating  the  new  gas  type  in  avisible 
location on the outside of the oven. The relevent tag is selected 
from those contained in the bag supplied with the appliance. 

 

8.  

SAFETY DEVICES 

The appliance is fitted with the following safety devices: 
 
Protection 

fuses

  (see  electrical  wiring  diagram)  mounted 

behind the control panel.  
To replace, unscrew the cap and replace the blown fuse with 
another of the same rating. The correct rating is indicated on 
the corresponding fuse plate. 
 
 

Oven  chamber  safety  thermostat 

(  manual  reset  type) 

mounted behind the control panel. The safety thermostat shut 
off  the  power  supply  to  the  convection  heating  system.  The 
thermostat  must  only  be  reset  by  qualified  technicans  after 
first eliminating the cause of the fault. 
 

Thermal cut-out 

inside 

fan motor. 

If the fan motor overheats, 

the  thermal  cut-out  trips  and  blows  fuse  F1,  causing  the 
appliance to shut down (see electrical wiring diagram). 
The  thermal  cut-out  must  only  be  reset  by  qualified 
technicans  after  first  eliminating  the  cause  of  the  fault  and 
replacing fuse F1 with another of the same rating. To replace 
the fuse, open the control panel, unscrew the  cap an replace 
the  blown  fuse  with  another  of  the  same  rating.  The  correct 
rating is indicated on the corresponding fuse plate. 
 
 

9. 

 OPERATION TEST 

 
-  Switch on the appliance following the instructions for use. 
-  Test the appliance for gas leaks. 
-  Test the operation of the gas exhaust system. 
-  Test  burner  ignition  and  flame  uniformity  by  removing  the 

RH  side  panel  (where  necessary)  and  checking  the  flame 
through the corresponding ports. 

-  Using  the  instructions  manual,  explain  the  operation, 

routine maintenance and cleaning instructions to the user. 

 
 
 
 
 
 
 
 
 
 

10.  SERVICING 

Access to components requiring routine maintenance may be 
easily gaind by opening the control panel or removing the LH 
side panel and rear panel. 

 

 
 

Important:  

The appliance is factory-set to the gas 

type  indicated  on  the  adhesive  labels  affixed  to 
both the appliance and packaging. To convert the 
aplliance  to  a  differenet  gas  supply,  scrupulously 
follow  the  instructions  indicated  below,  and  use 
the injectors in the bag supplied with the oven. 

Attention: 
After conversion, refit the oven outer panels.

 

Important:   
-

Exercise  due  care  since  certain  areas  of  the 

oven exerior get hot during use. 
-Do  not  cover  the  exhausts  on  top  of  the 
appliance. 

 

 

 

  

Summary of Contents for MKF-20G

Page 1: ...LUM KULLANIM VE BAKIM KILAVUZU GAS HEATED CONVECTION OVENS MKF 20G MKF 40G GN 1 1 INSTALLATION OPERATION AND MAINTENANCE MANUAL 2012 TLM 020 0041 ED NO 2 C HAZI KULLANMADAN NCE KULLANMA KILAVUZUNU MUT...

Page 2: ...ection 0 5 5 F M TR D Bo altma ya danl k P G kablosu giri i W Su ba lant s giri i 0 5 5 F M MKF 40G MKF 20G GB IE D Drain P Power supply inlet W Water supply connection 0 5 5 F M TR D Bo altma ya danl...

Page 3: ...sistemi 10 Gaz egzoz sistemi diyagram 11 4 Elektrik ba lant s 12 5 Su ana ba lant lar 12 6 Gaz ba lant s 12 7 Farkl tipte gazlar n d n m 13 8 Emniyet cihazlar 13 9 al ma testi 13 10 Servis 14 Tablo 2...

Page 4: ...cakl n g r lmesi ve ayarlanmas i in mikrostat F r n i kabin ayd nlatmas Mutfa a ve evreye daha az s da l m sa lanmas ve d k f r n d s cakl klar i in ift caml f r n kapa 2 ANA B LE ENLER Taral izgi il...

Page 5: ...5 MKF 40G 3 1 4 5 6...

Page 6: ...lant s giri i ISO 7 1 ap 1 2 M 1 2 M Nominal s giri i Kw 16 32 Gaz kategorisi II2H3B P II2H3B P Yap tipi B21 B21 Duman ekzoz sistemi fig r EK L 5 6 EK L 7 8 G20 do al gaz giri bas nc m bar 20 20 L P...

Page 7: ...l yedek par alar kullan larak yetkili servis merkezleri taraf ndan yap lmal d r Bu y k ml l e uyulmamas cihaz n g venli ini tehlikeye atar ve garantisini ge ersiz k labilir Ellerinizin yanmamas i in f...

Page 8: ...N N KORUNMASI 4 1 Paketleme Kullan lan t m ambalaj malzemeleri evre dostudur Bunlar hi bir risk te kil etmeden saklanabilir ve ya bir yakma tesisinde yak labilir Geri d n me uygun plastik malzemeler a...

Page 9: ...din Ambalaj evre korunmas ile ilgili b l mde anlat ld gibi at n z Cihaz n genel boyutlar ve ba lant lar i in bu el kitab n n ba nda bulunan kurulum emalar na bak n z Makinenin kurulum esnas nda sol ta...

Page 10: ...ferans alarak cihaz n yap t r n belirleyiniz b Kurulum yerinden egzoz gaz tahliyesi i in gereken gaz egzoz sisteminin t r n a a da g sterilen yap tipi diyagramlar ndan se iniz r davlumbaz d ar dan kan...

Page 11: ...ap rutin olarak kontrol edilmelidir Kesit daralmas ya anmamas i in kirlilik durumlar nda mutlaka temizlenmelidir nemli Tesisat ve davlumbaz i indeki filtrelerin bile enleri yan c olmayan malzemelerde...

Page 12: ...yerek d n m n ger ekle tiriniz Gaz n farkl tipte d n m Gaz ba lant s montaj a z sar renklidir Cihaz kurmadan nce tahmini t ketimi ve gaz talebinizin uyumlulu unu kontrol etmesi i in yerel gaz tedarik...

Page 13: ...ik ayg tlar ile donat lm t r Koruma sigortalar kontrol panelinin arkas na monte edilmi tir elektrik emas na bak n z De i tirmek i in kapa s k n ve yanm olan sigortayla o sigortayla ayn derecede olan b...

Page 14: ...jekt r B l m 7 2 G30 G31 L P G Propan Gaz 2 2 2 2 220 220 2 2 2 2 255 255 G20 Do al Gaz NG 3 0 3 0 300 300 3 0 3 0 300 300 Pilot yak c enjekt r B l m 7 4 G30 G31 L P G Propan Gaz n 24 n 24 n 24 n 24 G...

Page 15: ...i e itimli bir tesisat taraf ndan yap lmal d r A a daki bile enlere ula mak i in cihaz zerindeki kontrol panelini ve LH yan panelini a n z Su selenoid valfi G venlik ve i letim termostatlar Emniyet te...

Page 16: ...tutun 2 1 2 1 C HAZIN ALI TIRILMASI Su giri vanas n ve cihaz besleyen ana alteri a n z lk olarak B numaral anahtar 5 numaral pozisyona al n z E numaral g lambas yanacakt r I numaral gaz anahtar n sa a...

Page 17: ...deformasyon ezilme durumlar n kontrol edin gerekirse de i tirin Ba lant elemanlar uygun anahtar ile s k lerek difiz r yerinden kar l r ve f r n i kabinin temizlenmesi sa lan r Fan panelini tekrardan...

Page 18: ...oning 24 3 Gas exhaust system 25 Gas exhaust system diagrams 26 4 Electrical conection 27 5 Water main connections 27 6 Gas connection 27 7 Conversion to different type of gas 28 8 Safety devices 28 9...

Page 19: ...Temperature reading and configurating microstat probe only available on certain models Oven chamber lighting Double glazed oven door for reduced heat dispersion into the kitchen and low external oven...

Page 20: ...20 MKF 40G 3 1 4 5 6...

Page 21: ...ection inlet ISO 7 1 Diameter 1 2 M 1 2 M Nominal heat input Kw 16 32 Gas category II2H3B P II2H3B P Construction type B21 B21 Fume exhaust system figure Fig 5 6 Fig 7 8 G20 natural gas inlet pressure...

Page 22: ...rried out by authorised service centres using original spare parts Failure to comply with this obligation may jeopardise the safety of the appliance and invalidate the guarantee When the oven is hot o...

Page 23: ...ment CE CE marking IP Degree of protection 4 SAFEGUARDING THE ENVIRONMENT 4 1 Packaging All the packaging materials used are environmentally friemdly They may be stored at no risk or burnt at an autho...

Page 24: ...s instructed in the chapter on Safeguarding the environment Refer to the installation diagrams at the beginning of this handbook fort he appliance s overall dimensions and connections The RH side of t...

Page 25: ...g to Table 1 Technical Data or the appliance identification plate b Select the construction type diagram from those illustrated below featuring the type of gas exhaust system needed to evacuate the ex...

Page 26: ...tems Fig 1 and 5 the exhaust ducting must NOT exceed 3 metres in length OR vary in diameter and must be routinely checked and cleaned Important Make sure any extension ducting and the filters inside t...

Page 27: ...NGS Make sure the appliance corresponds with the gas supply to which it is connected If the appliance does nor correspond with the gas supply convert following the instructions given in section 7 belo...

Page 28: ...trol panel To replace unscrew the cap and replace the blown fuse with another of the same rating The correct rating is indicated on the corresponding fuse plate Oven chamber safety thermostat manual r...

Page 29: ...30 G31 L P G Propan Gas AU 2 2 2 2 220 220 2 2 2 2 255 255 G20 Natural Gas NG 3 0 3 0 300 300 3 0 3 0 300 300 Pilot burner injector Section 7 4 G30 G31 L P G Propan Gas AU n 24 n 24 n 24 n 24 G20 Natu...

Page 30: ...nce must only be carried out by a trained installer authorised by the manufacturer Open the control panel and LH side panel on the appliance to gain access to the following components Water solenoid v...

Page 31: ...the water and gas shut off valves 2 1 TURNING ON THE APPLIANCE Turn the water inlet valve and the main switch that feeds device First turn selector knob B to position 5 power led illuminates to indica...

Page 32: ...onnection cable and plug Yearly Check connection cable replace it if necessary and plug To facilitate the task of cleaning the oven remove the trolley mounted unit runners in the oven base if fitted a...

Page 33: ...33 MKF 20G MKF 40G KUMANDA PANEL CONTROL PANEL...

Reviews: