Maguire Products, Inc.
Rev. June 11, 2020
– ULTRA-600 Touchscreen
75
ULTRA By Maguire
- Ultra Low Energy Dryer
H1-10 Heat1 Set-Point Off. SO1 03002 03002 00000 65535 Sec/Deg
H1-11 Heat1 Max. Percent MP1 00100 00100 00000 00100 Percent
H1-12 Heat1 Restart Offset RO1 05040 05040 00000 65535 Pct/Sec
H1-13 Max Temp Set-Point MAX 00350 00350 00074 00375 Degree
H1-14 Energy Savings Mode ESM 00150 00150 00000 65535 Degree
H1-15 Energy Savings Time EST 00030 00030 00000 65535 Minute
H1-16 Ramp Settings RMP 52036 52036 00000 99999 Min/Deg
H1-17 Cool-Down Temp. CTM 00120 00120 00032 00300 Degree
H1-18 Cool-Down Timer CTR 00060 00060 00000 65535 Minutes
H2-1 Heat2 Temp Set-Point PGS 00150 00150 00074 00375 Degree
H2-2 Heat2 Proportional PT2 00030 00030 00000 65535 Term
H2-3 Heat2 Derivative DT2 00015 00015 00000 65535 Term
H2-4 Heat2 Update Time UT2 00830 00830 00000 65535 Second
H2-5 Heat2 OverTarg Alarm OT2 09006 09006 00000 65535 Sec/Deg
H2-6 Heat2 No Heat Alarm NH2 00180 00180 00000 65535 Second
H2-7 Heat2 Set-Point Off. SO2 00006 00006 00000 65535 Pct/Sec
H2-8 Heat2 Fixed Output FO2 00000 00000 00000 65535 Percent
H2-9 Dry Purge Delay DPD 00003 00003 00000 65535 Second
H2-10 Purge and Shutdown PST 00020 00020 00000 65535 Minutes
Load Cell:
L1 Loadcell Stable Wt. KDF 00200 00006 00000 65535 Number
L2 Loadcell Stable Time LST 00100 00100 00000 65535 Millisec
L3 Loadcell Zero LCZ 01000 01000 00000 65535 Number
L4 Weight Settle Time WST 01005 01005 00003 65535 Second
L5 Loadcell 1 Zero LZ1 00000 00000 00000 65535 Number
L6 Loadcell 2 Zero LZ2 00000 00000 00000 65535 Number
Vacuum:
V1 Vacuum Time Setting VTS 05020 05020 00001 65535 Minute
V2 Vac. Pressure Low VPL 00125 00125 00000 65535 Number
V3 Vac. Pressure Delta VPD 00020 00020 00000 65535 Number
V4 Vac. Shutdown Offset VSO 00060 00060 00000 65535 Second
V5 Low Vacuum Timeout LVT 00150 00150 00000 65535 Second
V6 No Vacuum Timeout NVT 00345 00345 00000 65535 Cnt/Sec
V7 Cham. Purge Timer VPT 00015 00015 00000 65535 Second
V8 Cham. Purge Interval VPI 35240 35240 00000 65535 Sec/Sec
V9 Atmospheric Pressure ATM 00760 00760 00000 00999 mmHg
System:
S1 Event Logging Time ELT 00060 00060 00001 65535 Second
Alarm Flags:
Material Shortage Alarm Warn
Material Ready Off
Material Temp Off
HH Level Alarm Off
Residence Off
Throughput Alarm On
Dump Retry On
Display Flags:
Auto Shutdown Off
Batch Mode Off
Cycle Info On
Display Temp.
Fill Time On
Dump Time On
I/O Status On
Preheat Temp Off
Preheat Temp. On
Residence Time Off
Screen Timeout Off
Vacuum Time On
Heat Settings:
Temperature Unit Fahrenheit
Preheat Mode Timed
Energy Saver Off
Ramp Off
DryPurge Temp. Auto