MPT-333
Converting the locking unit
IMPORTANT!
You can modify the locking unit into the "normally closed" con-
figuration. You must then parameterise the turnstile for the
"Normally closed" configuration in the "Gate HW" menu. For pa-
rameterisation see separate document "Description of MGC con-
trol unit for MPT-333 Full Height Turnstile (Doc.ID: 5817,0027)".
Characteristic
Normally open
Normally closed
Function
The centre pillar can be rotated in
the event of a power failure. The pas-
sage is free for both directions.
In the event of a power failure, the
passage is blocked for both direc-
tions. The centre pillar is locked.
Required washers
6 washers: 3 inner, 3 outer
5 washers: 3 inner, 2 outer
Table 9:
Characteristics "Normally open" and "Normally closed”
Convert locking unit for configuration "Normally closed"
1. Disconnect the pedestrian gate from the power supply. Ensure that the
system is powered down. Secure against reactivation.
DANGER
Danger to life, electrical voltage!
2. Open top cover.
ä
ä
Mag0088
8
Fig. 38: Locking unit configuration "Normally open"