![background image](http://html1.mh-extra.com/html/magnetek/telemotive-tr12-intelesmart/telemotive-tr12-intelesmart_instruction-manual_3587676020.webp)
Section 6 - Wiring (continued)
Telemotive TR12 inteleSmart Receiver Instruction Manual – 03/01/07
18
Note:
Move jumper JU1 on the Receiver Board for Alarm after an E-Stop command to function.
See Figure 8-1. Receiver Layout for Jumper JU1 location and position.
TABLE 1. SINGLE-SPEED WIRING DIAGRAM.
STANDARD CONFIGURATION HOIST, TROLLEY AND BRIDGE
Receiver Panel
J10-2
J9-5
J9-3
J9-1
J8-5
J8-3
J8-1
J7-5
J7-3
J7-1
J6-5
J6-3
J6-1
HOT
J10-3
J9-6
J9-4
J9-2
J8-6
J8-4
J8-2
J7-6
J7-4
J7-2
J6-6
J6-4
J6-2
RETURN
MLC
C12
C11
C10
C9
C8
C7
C6
C5
C4
C3
C2
C1
J10-8
J10-7
J10-6
J10-5
J10-4
J10-3
J10-2
J10-1
J9-6
J9-5
J9-4
J9-3
J9-2
J9-1
J8-6
J8-5
J8-4
J8-3
J8-2
J8-1
J7-6
J7-5
J7-4
J7-3
J7-2
J7-1
J6-6
J6-5
J6-4
J6-3
J6-2
J6-1
J10-4 J10-5
External jumper
in J10 connector
F14
F13
F12
F11
F10
F9
F8
F7
F6
F5
F4
F3
F2
K13
K12
K11
K10
K9
K8
K7
K6
K5
K4
K3
K2
K1
MASTER RELAY
MAIN LINE CONTACTOR
2
(Alarm, optional)
1
(latchable Rx S2-3)
3
(latchable Rx S2-2)
7
4
8
9
5
10
11
6
12
ON/
OFF
6
5
4
3
2
E-STOP
7
8
9
10
11
12
1
telePilot
Single-
S
p
eed transmitte
r
The numbers on the
Single-Speed outputs match
the respective numbers on
telePilot
function buttons