F05
CPF-05 – AD converter fault
is detected.
F06
CPF-06 – a prohibited option
is detected.
Turn the power supply off,
the on again. If the fault
remains, replace the drive.
OFF
OFF
– – –
• Control power supply fault
• Hardware fault
Check the power supply
wiring. Replace the drive.
Turn the power supply off,
remove the option, then turn
it on again.
F04
CPF-04 – constant fault is
detected.
Record all constant data
and reinitialize the
constants. Turn the power
supply off, then on again.
If the fault remains, replace
the drive.