C
Cu
urrrre
en
ntt R
Re
effe
erre
en
nc
ce
e IIn
np
pu
utt::
CAUTION
Do not remove the Digital Operator to access the dipswitch unless the input
power to the drive has been turned OFF.
When setting frequency by current
reference (4-20mA) from the control
circuit terminal FR, move dipswitch
SW1 on the printed circuit board to
the “
I
” position. SW1 is accessed
by removing the Digital Operator.
After switching SW1, set the MODE
Function LED to “ 4 ” or “ 5 ”.
Setting 4 :
• Use Digital Operator to give
RUN/STOP command. Use the F
F /
/ R
R
LED to alternate between FWD
and REV run.
•
Set frequency with analog
current signal ( 0-100% of max.
frequency = 4-20mA ) at control
circuit terminal FR.
Setting 5 :
• Use switches connected to the
control circuit terminals to
alternate between FWD RUN/STOP
and REV RUN/STOP.
•
Set frequency with analog
current signal ( 0-100% of max.
frequency = 4-20mA ) at control
circuit terminal FR.
Frequency command gain and bias (n
n 3
3 9
9 , n
n 4
4 0
0 ) can be set even when current
reference input is selected. For details, refer to page 45.
25
DIGITAL
OPERATOR
REMOVED
CONNECTOR
FOR
DIGITAL
OPERATOR
DIPSWITCH
SW1
V
I
GPD
205
AC
MOTOR
FS
FR
FC
CURRENT
REFERENCE
4-20mA
GPD
205
AC
MOTOR
FS
FR
FC
CURENT
REFERENCE
4-20mA
SF
SR
SC
FWD RUN/STOP
REV RUN/STOP