![background image](http://html1.mh-extra.com/html/magnetek/electrobar-fs/electrobar-fs_instruction-manual_3572977018.webp)
Electrification FS Conductor Bar System Instruction Manual
October 2019
Page
18
of
34
5.2.(b):
Remove packaging foam.
5.2.(c):
Center joint cover over joint assembly.
5.2.(d):
With light pressure, open the bottom of the joint cover sufficient to clear the sides of the
line element. Damage may occur to joint cover if it is spread beyond 1¼” wide.
5.2.(e):
Push joint cover down until lower lips of cover clear the bottom of the line element. If
cover does not clear bottom of line element, verify the cover is centered between joint assembly
bolts.
5.2.(f):
Push on sides of joint cover so lips are positioned under the line elements.
5.2.(g):
Pull up on the joint cover so the lips are in contact with bottom of the line element cover
and insulate the vertical face of the exposed conductor bar.
5.2.(h):
Fold down flaps at each end of the joint cover.
5.2.(i):
Fold the locking tabs around the side of the joint cover and snap them into the slots along
the side of the joint cover.
5.3: End
Cover
(FS-END)
5.3.(a):
Verify that the clamping plate is 1/8” below the underside of the end joint connector. If it
is not, loosen or tighten the nuts to make the adjustment.
5.3.(b):
Slide end cap hardware into slot at end of the line element.