22
AFTER SALES SUPPORT
AUS
1800 623 432
MODEL: IPC-100 AC
PRODUCT CODE: 91838
12/2014
In the below example, this can be found under “Applications & Games“ as “Simple Port forwarding”.
In the provided example two IP Security Cameras are connected to the router, one camera with the name
IPCamera1
and
the local network address 192.168.1.110, a second camera with the name
IPCamera2
and the local network address
192.168.1.111.
Only the external port 81 is set up for the IP Security Camera IPCamera1. TCP and UDP are the allowed protocols although only
TCP is required. These cameras are accessed via the internet using address
http://xxx.xxx.xxx.xxx:81
(with xxx.xxx.xxx.xxx
being the public IP address of the router).
In order to avoid problems the same internal and external port of the IP Security Camera should be chosen. Activate the
IP Security Camera again using the program “
Maginon IPCam Config”
. Under “Settings” change to “Network settings” and
change the value under “Port” also to 81. Save the changes.
You should then be able to access the IP Security Camera via the camera as described at the beginning of this section.
Note:
• Ensure that for every existing IP Security Camera a separate port is being used and that an external Port may not be
assigned twice.