Shutoff Thermostats
By setting the temperature value for each operating power, if the fume temperature falls below
the value set for the corresponding power in operation, the system goes into Shutdown with
Er03.
Parameter Function Description
Garda
18
Garda
21
Garda
28
U.M
Th35
Shutoff at Power 1
45
45
45
°C
Th36
Shutoff at Power 2
45
45
45
°C
Th37
Shutoff at Power 3
45
45
45
°C
Th38
Shutoff at Power 4
45
45
45
°C
Th39
Shutoff at Power 5
45
45
45
°C
Th40
Shutoff at Power 6 (not used)
45
45
45
°C
Th43
Shutoff at Modulation Power
45
45
45
°C
Time Menu
Parameter Function Description
Garda
18
Garda
21
Garda
28
U.M
T01
Speed at Ignition
-
20
20
sec
T02
Glowplug preheat
-
60
60
sec
T03
Pre-charge at Ignition
-
63
86
sec
T04
Fixed Ignition
-
120
120
sec
T05
Variable Ignition
-
400
400
sec
T06
Stabilization
-
300
315
sec
T07
Periodic cleaning repetition
-
20
20
min
T08
Periodic cleaning duration
-
30
30
sec
T09
High Voltage 1 Safety Delay
-
5
5
sec
T10
High Voltage 2 Safety Delay
-
120
120
sec
T11
Delay exit in Standby
-
10
10
sec
T13
Minimum duration of Shutoff phase
-
180
180
sec
T14
Pre-shutoff
-
120
120
sec
T15
Safe Shutoff
-
60
60
sec
T16
Final cleaning at Shutoff
-
240
240
sec
T17
Power upgrade
-
10
10
sec
T18
Ignition power upgrade
-
60
60
sec
T22
Delayed entry in Standby
-
10
10
sec
T23
Fuel tank filling timer (Not used)
-
10
10
sec
T24
Waiting for pellet loading in the tank (Not used)
-
20
20
sec
T27
Pallet safety valve deactivation delay (Not used)
-
30
30
sec
T29
Auger turned off at Preload
-
120
120
sec
T30
Exchanger Cleaning Engine Working time (Not used)
-
30
30
sec
T31
Exchanger Cleaning Interval (Not used)
-
2
2
min
T32
Waiting time for brazier maintenance in Standby
-
30
30
min
T33
Operation time for brazier maintenance in Standby
-
20
20
sec
T34
Auger activation time in case of flame return
-
0
0
sec
T40
Auger activation delay (if set)
-
0
0
sec
T41
Pump P1 working time if T42 has expired
-
30
30
sec
T42
Maximum inactivity time of Pump P1 and Pump P2 or
solenoid valve
-
120
120
hours
T43
Timer to switch from Modulation to Standby if boiler
temperature is> (Boiler Ther D23) and A13 = 1
-
90
90
sec
T46
Valve working time if T42 has expired
-
90
90
sec