16
2
Heating fan (Optional)
Parameter Description Function
Garda
18
Garda
21
Garda
28
U.M
F01
Power 1
130
130
130
Volt
F02
Power 2
150
150
150
Volt
F03
Power 3
180
180
180
Volt
F04
Power 4
200
200
200
Volt
F05
Power 5
230
230
230
Volt
P06
Heating management:
1
=Heating power as combustion
power;
2
=Heating power proportional to flue gas
temperature;
3
=Heating power proportional to room
temperature
3
3
3
nr
Thermostats
Parameter Description Function
Garda
18
Garda
21
Garda
28
U.M
Th01
Thermostat at stove off
50
50
50
°C
Th02
Glowplug deactivation thermostat
55
55
55
°C
Th03
Thermostat for pre-switch off due to lack of flame
45
45
45
°C
Th05
Heating fan activation thermostat
70
70
70
°C
Th06
Thermostat for passage from Stabilization to Variable-phase
Step
50
50
50
°C
Th07
Fume modulation
180
180
180
°C
Th08
Fume safety
200
200
200
°C
Th09
Ignition Bypass Thermostat
100
100
100
°C
Th18
Anti-freeze Thermostat
5
5
5
°C
Th19
Pump P1 activation thermostat
50
50
50
°C
Ih19
Pump P1 activation Thermostat Hysteresis
2
2
2
°C
Th20
Sanitary 1 Thermostat
55
55
55
°C
Th21
Sanitary 2 Thermostat
80
80
80
°C
Ih21
Sanitary 2 Thermostat Hysteresis
10
10
10
°C
Ih24
Boiler Thermostat Hysteresis
3
3
3
°C
Th25
Boiler Safety Thermostat
90
90
90
°C
Th26
Boiler Thermostat Minimum range
50
50
50
°C
Th27
Maximum Boiler Thermostat Range
75
75
75
°C
Th28
Fume Temperature Control in Standby
90
90
90
°C
Ih33
Ambient Thermostat Hysteresis
1
1
1
°C
Th56
Thermostat-controlled Output Thermostat
50
50
50
°C
Ih56
Thermostat-controlled Output Thermostat Hysteresis
1
1
1
°C
Th57
Boiler Probe - Boiler Probe Differential
5
5
5
°C
Ih57
Differential Thermostat Hysteresis
1
1
1
°C
Ih58
Boiler Thermostat Hysteresis
3
3
3
°C
Th59
Pump P2 activation Thermostat (only if P26=4)
60
60
60
°C
Ih59
Pump P2 activation Thermostat Hysteresis (only if P26=4)
2
2
2
°C
Th60
Thermostat-controlled Output 2 Thermostat
50
50
50
°C
Ih60
Thermostat-controlled Output 2 Thermostat Hysteresis
1
1
1
°C