background image

MADE

 

IN

 

ITALY

design & production

MIRKA - MIRKA PLUS

004281275 - Rev 001

UK

PeLLet StoveS USeR MANUAL

Summary of Contents for MIRKA

Page 1: ...MADE IN ITALY design production MIRKA MIRKA PLUS 004281275 Rev 001 UK pellet stoves USER MANUAL ...

Page 2: ...2 ENGLISH APPLY TECHNICAL DATA LABEL ...

Page 3: ...2 AIR ZONE CONTROL MIRKA PLUS 23 EASY SETUP 23 CHRONO 23 ENABLING 24 CHRONO MODE 24 PRG 1 4 24 EXAMPLE 25 Chrono time slot 25 MANUAL 25 SET TEMPERATURE 25 AUX 25 SETTINGS 26 DISPLAY 26 STAND BY 26 OPERATION WITH ADDITIONAL THERMOSTAT OPTIONAL 26 DELTA T 27 FIRST LOAD 27 RESET 27 EASY CONTROL 27 ADDITIONAL FUNCTIONS 28 Additional thermostat INSTALLATION optional 28 DELAY SWITCH OFF 28 Cleaning and ...

Page 4: ...iance has been installed as well as the instructions contained in this manual The use of the appliance must comply with all local regional national and European regulations The Manufacturer cannot be held responsible for the failure to comply with such precautions After removing the packaging ensure that the content is intact and com plete Otherwise contact the dealer where the appliance was purch...

Page 5: ...N IF IT IS DISCONNECTED FROMTHE MAINS It is advised to position the power supply cable so that it does not come into contact with hot parts ofthe appliance The power supply plug must be accessible after installation Do not close or reducethe dimensions ofthe airingvents in the place of installation The airing vents are essential for correct combustion Do not leave the packaging elements within rea...

Page 6: ... clean the majolicas it is recommended to use a soft dry cloth If a detergent or liquid is used the latter could penetrate inside the crackles highlighting them SINCE THE PRODUCT CAN TURN ON AUTOMATICALLY THANKS TO THE TIMER OR REMOTELY USING THE DEDICATED APPLICATIONS IT IS STRICTLY FORBIDDEN TO LEAVE ANY COMBUSTIBLE OBJECT WITHIN THE SAFETY DISTANCES INDICATED ON THE TECHNICAL DATA PLATE interna...

Page 7: ...omestichotwaterproductionandinadjacentandcommunicating rooms 3 where the depression measured in situ between the external and internal environment is greater than 4 Pa N B Watertight appliances can also be installed in the cases indicated in points 1 2 and 3 of this paragraph Installations in bathrooms bedrooms and studio flats Installation in bathrooms bedrooms and studio flats is only allowed fo...

Page 8: ...t always be insulated The smoke ducts must have at least one airtight inlet for flue gas sampling All the sections of the flue gas duct must be accessible to inspection Inspection openings must be provided for cleaning If the generator has a fume temperature lower than 160 C ambient temperature caused by the high yield contact technicians it MUST be resistant to humidity Afluesystemthatdoesnotresp...

Page 9: ...Room air outlet D Pellet hopper G Room probe B Access to combustion chamber and ash drawer E Rear flue gas outlet H On Off fuse 230 V power supply C Upper fumes exhaust F Additional thermostat input I Bulb thermostat reactivation J Combustion air inlet ...

Page 10: ...air outlet D Pellet hopper H On Off fuse 230 V power supply B Access to combustion chamber and ash drawer E Rear flue gas outlet I Bulb thermostat reactivation C Upper fumes exhaust F Additional thermostat inlet J Combustion air inlet G Room probe K Ducting outlet ...

Page 11: ...hapter UPPER FUMES OUTLET ASSEMBLY the conversion ofthe upper flue gas outlet MUST BE CARRIED OUT BY QUALIFIED PERSONNEL AND ORTHE MANUFACTURER S TECHNICIANS Upper FUMES OUTLET assembly FOLLOW THE ASSEMBLY INSTRUCTIONS CAREFULLY ALWAYS FOLLOW THE ASSEMBLY INSTRUCTIONS IN COMPLETE SAFETY THE STOVE MUST BE COMPLETELY COLD SWITCHED OFF AND DISCONNECTED FROM THE ELECTRICAL POWER SUPPLY NOT SUPPLIED ...

Page 12: ...losed the air ducting motor will follow the stove settings when the temperature has been reached contact open the motor will switch off The duct thermostat terminal features a standard bridge See the example image HOT AIR DUCTING The machine leaves the factory with the ducting disabled The pipe used for ducting the hot air must have an internal diameter of 80 mm and it must also be insulated or at...

Page 13: ... on the thermostat is reached OPEN CONTACT the ducting motor will switch off and switch on again when there is a new request SET on BOOST The temperature setting is not visible Once the specific activation threshold has been reached and exceeded at temperature to be satisfied CLOSED CONTACT the air ducting motor will follow the stove settings but at a higher speed than in REGULAR for faster heat e...

Page 14: ...on means that you have 60 seconds to close the hatch door and the pellet lid After the 60 seconds during ignition the stove will go into DEPR ALARM mode while during normal operation the stove will go into COOLING WAITING TIME mode before automatically resuming operation once the conditions are satisfied cold stove etc bulb thermostat reactivation The figure shows the position of the hopper safety...

Page 15: ...es are used for its compaction In fact pellet compactness is guaranteed over time by a natural substance found in wood lignin In addition to being an ecological fuel making best use of wood residue pellets also have a series of technical advantages While wood has a calorific value of 4 4 kWh kg with 15 moisture therefore after approximately 18 months of curing that of pellets is 5 kWh kg Pellet de...

Page 16: ...ock keyboard 3 On off stove hold for 3 seconds 9 Degrees Celsius Fahrenheit 4 Set power 10 Press the button once to enable or disable the chrono 5 Set switch off delay The button allows to set the switch off delay For example if you set it to one hour the stove will automatically switch off after the set time 11 Reset 6 Set room temperature 12 Battery compartment ...

Page 17: ...ignal receiver Handle the remote control with care When it is not being used place it on the special base supplied The remote control must not be left in a place where it is exposed to direct sunlight or near a source of heat The quality of the signal may be affected by other IR sources Air mode selected Flashing COMFORT On AUTO Enable chrono Light on activated Light off deactivated Set switch off...

Page 18: ...tat Closed contact the contact of the external additional thermostat is closed Open contact the contact of the external additional thermostat is open Icon visible only if MODE is set to AUX WI FI BT STBY OK ON STAND BY function icon Off deactivated On activated OK Indicates the stove power Flame on stable power Flame flashing the power is increasing or decreasing The dashes indicate the actual pow...

Page 19: ...al stone parts from the top part of the product Activate the product at the maximum power and temperature Avoid remaining in the room for a long time Do not touch the surfaces of the product Notes The process is completed after a few heating cooling cycles For combustion do not use elements or substances other than those indicated in the manual Before turning on the product it is necessary to perf...

Page 20: ...rs and confirm by pressing key 6 Select the language using keys 4 or 5 Press key 6 to confirm and key 1 to scroll back through the menus until the initial page Degrees This menu allows you to set the unit of measurement for the temperature The predefined value is C CONTROLS PROCEDURE Press key 6 Press key 3 until SETTINGS appears and confirm by pressing key 6 Press key 3 until DEGREES appears and ...

Page 21: ...es off if STAND BY mode is active If the contact is closed request the stove works at the set power Regulation of SET POWER Set Power has 5 levels of operation The power can be changed with keys 2 or 3 Power 1 minimum level Power 5 maximum level Press key 1 to exit and save the change AUTO BLOW During the work phase the stove cleans the burn pot at regular intervals with the function called AUTO B...

Page 22: ...according to the set settings with the contact open the stove switches to minimum modulation or it switches off if the STAND BY function is active CONTROLS PROCEDURE Press key 6 Press 3 until MODE appears and confirm by pressing 6 Use keys 4 5 to set the desired MODE Press key 6 to confirm and key 1 to scroll back through the menus until the initial page Acoustic comfort HEATING SPEED OFF QUIET RE...

Page 23: ...ected the stove will optimise the adjustments so that the heat is sent to the ducting when the main room temperature set is reached CONTROLS PROCEDURE Press key 6 Press 3 until AIR ZONE CONTROL appears and confirm by pressing 6 Use keys 4 5 to enable ON or disable OFF Press key 6 to confirm and key 1 to scroll back through the menus until the initial page When the function is active AIR ZONE CONTR...

Page 24: ...ss 3 until CHRONO appears and confirm by pressing key 6 Press 3 until PRG 1 4 appears and confirm by pressing 6 Use keys 4 5 to set the preferences Press key 6 to confirm and key 1 to scroll back through the menus until the initial page CHRONO ENABLING PRG 1 ON OFF Enable disable PRG 1 PRG 2 ON OFF Enable disable PRG 2 PRG 3 ON OFF Enable disable PRG 3 PRG 4 ON OFF Enable disable PRG 4 CHRONO MODE...

Page 25: ...Power Time slot 1 Start 02 00 Stop 23 00 Power 5 02 00 23 00 08 00 16 30 t 02 00 23 00 08 00 16 30 t 5 1 22 2 1 Time slot 2 Start 08 00 Stop 16 30 Power 1 Stove setting if TA contact closed SET TEMPERATURE Power Set Thermostat 02 00 23 00 08 00 16 30 t 02 00 23 00 08 00 16 30 t 5 1 02 00 23 00 08 00 16 30 t 22 18 2 1 h 02 00 23 00 08 00 16 30 t 02 00 23 00 08 00 16 30 t 5 1 02 00 23 00 08 00 16 30...

Page 26: ...en the room temperature set on the additional thermostat is reached open contact the stove will switch off after a preset delay and STAND BY will appear on the screen When the room temperature is less than the set temperature on the additional thermostat closed contact and after a certain cooling time the stove ignites again J When STAND BY and AIR ZONE CONTROL are active the generator is switched...

Page 27: ...n allows the hysteresis thresholds to be set for stove ignition DELTA T ON and switch off DELTA T OFF used as a room temperature adjustment interval if not managed by an external thermostat The possible values for DELTA T go from 0 5 5 C CONTROLS PROCEDURE Press key 6 Press key 3 until SETTINGS appears and confirm by pressing key 6 Press key 3 until DELTA T appears and confirm by pressing key 6 Us...

Page 28: ...ust be performed by qualified staff and or the manufacturer s service technicians ADDITIONAL FUNCTIONS Additional thermostat INSTALLATION optional The stove can control the room temperature through an additional thermostat optional After ignition by pressing key 6 or in chrono mode the stove will work to reach the set value on the thermostat displaying WORK closed contact on the screen The standar...

Page 29: ...ranty Cleaning the ceramic glass Never use abrasive or chemically aggressive detergents for cleaning The ceramic glass must be cleaned when the glass is completely cold To clean the ceramic glass simply use a dry brush and some damp newspaper dipped in ash If the glass is very dirty use a specific cleaning agent for ceramic glass Spray a small amount on a cloth and use it on the ceramic glass Do n...

Page 30: ... relevant compartment Vacuum the ash from the burn pot slot ignition plug pipe holder and combustion chamber Clear clean all the holes in the burn pot Re position the burn pot in its slot and push it towards the fire wall NOTE Use a suitable ash vacuum cleaner with a special separate container for the collected ashes ...

Page 31: ...ER MENU CAN BE USED TO ADAPT COMBUSTION ACCORDING TO THE NEEDS DESCRIBED BURN POT HOLES How often the ash drawer is emptied depends on a number of factors the type of pellets the stove output the use of the stove and the type of installation Average use 8h at max nominal power PARTS FREQUENCY IN DAYS BURN POT USER 2 COMBUSTION CHAMBER USER 2 REMOVABLE ASH DRAWER USER 2 T SHAPED FITTING smoke duct ...

Page 32: ...echnical assistance Requests for routine maintenance are not covered by the warranty GASKETS pellet hopper lid DOOR ASH DRAWER AND BURN POT INSPECTION OF SMOKE DUCTS The gaskets ensure the proper sealing of the stove and therefore its proper operation They must be periodically checked and immediately replaced if worn or damaged These operations must be carried out by a qualified technician CONNECT...

Page 33: ... apply silicone where indicated C Combustion chamber exchanger total cleaning including cleaning the glow plug duct and EGR duct D Hopper complete emptying and cleaning E Check the air intake pipe and check clean the mechanical pressure switch F Remove the room air fan and remove any dust and pellet residue TO FIND OUT WHERE YOUR NEAREST SERVICE CENTRE IS CONTACT YOUR DEALER OR VISIT THE WEBSITE W...

Page 34: ... and apply silicone where indicated C Combustion chamber exchanger total cleaning including cleaning the glow plug duct and EGR duct D Hopper complete emptying and cleaning E Check the air intake pipe and check clean the mechanical pressure switch F Remove the room air fan and remove any dust and pellet residue TO FIND OUT WHERE YOUR NEAREST SERVICE CENTRE IS CONTACT YOUR DEALER OR VISIT THE WEBSI...

Page 35: ... EXPLANATION SOLUTION Indicates the presence of an alarm On indicates the presence of an alarm The alarm can only be reset if the fumes motor has stopped and 15 minutes have passed since the alarm was displayed by pressing key 6 for 3 seconds Fumes motor Fault Fumes motor fault Contact after sales centre Fumes probe Fumes probe fault Contact after sales centre Hot fumes High fumes temperature Chec...

Page 36: ...ger and the fume pipe of the appliance Clean clear the T shaped fitting the flue pipe and the chimney flue DELTA P FAULT Differential pressure transducer faulty or disconnected Contact after sales centre MINIMUM DELTA P ALARM The ash drawer is not closed correctly The air intake is clogged The combustion chamber is dirty The holes in the burn pot are clogged The heat exchanger and or the fume pipe...

Page 37: ... kindly asked to separate this equipment and or batteries or accumulators included from other types of waste and to arrange for disposal by the municipal waste service It is possible to ask your local dealer to collect the waste electric or electronic appliance under the conditions and following the methods provided by national laws transposing the Directive 2012 19 EU Separate waste collection an...

Page 38: ...38 ENGLISH ...

Page 39: ...39 ENGLISH ...

Page 40: ...Y 39 0445 865911 39 0445 865912 info extraflame it www lanordica extraflame com TO FIND THE SERVICE CENTRE NEAREST TO YOU CONTACT YOUR DEALER OR CONSULT THE SITE WWW LANORDICA EXTRAFLAME COM The manufacturer reserves the right to vary the characteristics and the data reported in this pamphlet at any moment and without notice in order to improve its products ...

Reviews: