Page 24
L
Surround/
False Chimney
Breast
200mm
min
Terminal/
Air Duct
Base
Figure 32
11. Apply the fire cement supplied around
each of the duct spigots on the rear of
the appliance.
12. Push the two lengths of duct previously
cut on to the duct spigots. Make sure the
ducts are pushed fully home up to the
firebox.
13. Position the firebox complete with ducts
attached centrally into the fire opening.
Thread the cables through the eye-
screws. With the firebox placed close to
the fireplace opening feed the two cables
through the matching eye screws (left
cable through left hand set of eyelets
and the same for right hand cable) and
then back into the holes at the bottom
rear of the firebox (see
Remove the grommet from the gas inlet
slot on the firebox to allow for gas pipe to
come through. Whilst pulling the cables,
push the firebox gently into the opening
(ensuring that the gas pipe emerges
from the rear slot) until the flange of the
firebox abuts the fire surround (or the
wall).
14. Feed each bare cable end into the hole
in the brackets on the base of the firebox
and in turn through the hole at the
threaded end of the cable tensioning
screw. (See
15. Slide each of the tensioning screws all
the way onto the cable and through the
hole in the bracket.
16. Whilst holding the cable tensioning
screw in the bracket pull the cable taught
and without releasing the tension tighten
the thumb screw firmly. To further tighten
the cables, screw the wing nuts
clockwise.
17. Roll up the excess cable and tuck it
away. Do
NOT CUT
the excess cable.