Page 7
2.2.3.
Lighting Procedure (Total Control)
1. Ensure that gas is available at the valve
and the ON/OFF switch in the ON
position (
–
). (See
2. Simultaneously press and hold the
(red circle) and
(large flame)
buttons until a short acoustic signal
confirms the start sequence has begun,
then release the buttons (see
3. The pilot flame should stay alight. If the
flame goes out repeat the procedure
above to establish the pilot. Due to
safety and the efficient way the fire
works, it is not unusual for the pilot to
stay alight only after the second or even
third attempt.
4. Continuing signals confirm the ignition is
in process.
Once the pilot is lit the gas
rate adjusting knob automatically
turns to high gas rate
. The main
burner cross-lights from the pilot.
5. To adjust the gas rate to desired setting
press the
(large flame) to increase the
flame height or (small flame) to
decrease the flame height on the
handset (see
6. For fine adjustment tap the
or
buttons.
7. To leave the burner in the
standby
mode
press the (small flame) until the
main burner goes out. In the standby
mode the pilot stays alight.
8. To
turn off
the main burner and the pilot
press the ‘OFF’ button on the hand set.
Figure 9
Figure 10