16
MAGENTA MONDO MATRIX
CHAPTER 3: Installation
3. Installation
1. Install the Mondo III Matrix switch frames in a suitable rack fixture. The Mondo III Matrix is designed to
install into a standard 19” wide cabinet. It is recommended to install all Mondo III Matrix hardware in a
restricted access location such as a secure equipment room. Ensure there is adequate ventilation space on
side and rear of unit. It is not necessary to allow ventilation space above or below each frame.
WARNING
This equipment is not intended for, nor does it support, distribution through an Ethernet
network. Do not connect these devices to any sort of networking or telecommunications
equipment!
Not for direct connection to the telecommunication network circuitry (TNV)
This equipment is to be installed in a restricted access location only.
Product may be powered by redundant power sources. Disconnect all power sources
before servicing.
2. Before any cables are connected, determine the Input / Output assignments for each switch frame. The
address assigned to the switch frame determines the Input / Output range in the Mondo III Matrix system.
See Table 1 in Section 2.2 for frame address schemes. If the Mondo III SAP option has been purchased,
ensure the frames with the SAP COM ports are in the last column. Reference Section 6, Mondo III SAP
Usage.
3. Apply power to each individual Mondo III Matrix frame and verify (or assign) proper switch frame addresses
according to intended Input / Output assignments. Each switch frame must have a unique address. Use the
configuration LCD to configure the address. Press the MENU button until FRAME ADDRESS is shown. The
Press UP/DOWN buttons to change address if necessary. Finally press the OK button to save changes.
See Section 4 for details on other configuration parameters.
14
Frame Address:
000