![Magenta Mondo III Matrix Installation & Setup Manual Download Page 23](http://html1.mh-extra.com/html/magenta/mondo-iii-matrix/mondo-iii-matrix_installation-and-setup-manual_3418143023.webp)
.
23
5. Commands
Mondo III Matrix Serial Communications Requirements:
9600 Baud (default baud rate, selectable via LCD menu. See Chapter 4)
8-bit, No Parity, One Stop Bit
No Handshaking is required
Characters sent to the Mondo III Matrix are not echoed back to the controller. If using a simple terminal application,
enable the local echo option.
The Mondo III Matrix will reply with either “OK>“ (command accepted) or “ERxx>“ (error, command not recognized)
after a command string is sent.
Error codes are:
ER00
=
Reserved
ER01
=
Reserved
ER02 = Error, command not recognized or executed
ER03 = System locked. Try again later
Note that all commands are terminated with a carriage return <CR> (0A hex).
The Mondo III Matrix responds back with data output terminated with <LF><CR> characters (0D hex, 0A hex).
An entire command string may be sent without any character pacing delays, however it is recommended to wait for
the “OK>“ ready prompt from the switch before sending the next command string.
The Mondo III Matrix master frame outputs information on its hardware and firmware platform as well as how many
frames are connected at power up. This can be useful to troubleshoot Mondo III Matrix communication errors and
how many frames the master has found.
Following is the complete Mondo III Matrix Command set (commands designated with an M3 note are only
supported in Mondo III mode and with Mondo III frames):
General Commands:
#C = Clear all output assignments - sets all Outputs to OFF (routes to input 0).
#I = Initialize system.
Master frame will detect slave frames and restore power up crosspoint map.
Similar to power cycling the master frame.
S = Save current crosspoint map into memory.
This map is restored after power up or when the #I or R command is given.
R = Restore power on crosspoint map.
#$ = Enable Auto-Save: Current cross-point map is saved into memory and will be
restored at power up, or if an #I, R command is received
#& = Disable Auto-Save: Current cross-point map will not be saved into memory
21