44
English
Static Survey Setup
It is assumed that you have already run all the instructions de-
tailed in
Chapter 2. Preparing For First-Time Use on page 4
.
Follow the instructions below to run both the base and the rov-
er.
1. Turn on the receiver by pressing the
red key.
2. Double-tap the
Surveying
icon.
3. If you have a ProMark3 RTK, press MENU, tap
Receiver
Mode
and then
Post-processing
.
4. Press the NAV key until you see the Satellite Status screen
(see opposite). Wait until at least 4 satellites are received.
5. When there is enough satellites received, press the LOG
key. The
Survey Settings
screen opens.
6. Enter the following parameters:
•
Site ID
: A 4-character string.
•
Survey Mode
:
Static
.
•
Site Description
: An optional 20-character narrative
description of the point.
•
Antenna Height
: From the reference point.
Satellite Status screen