SIGMA LASER STENT AND TUBE CUTTER
6
990-401
9.
Locate the Gas Input on the facilities panel on the back of the machine.
10.
Connect regulated 100-120psi to Air Input
with 6mm polytube. Make sure the air has
water/oil filter trap in line.
11.
Connect regulated 50-300psi Oxygen to
Assist Gas Input with 6mm high pressure
(Festo) tube. For cutting it is recommended
to use liquid oxygen dewers. At a
minimum if oxygen cylinders are being
used they should be 99.999 purity.
12.
Locate the main breaker on the facilities
panel on the back of the machine, turn the
switch ON.
13.
Again insure there are no obstructions on
the motion system of any type before
moving the systems main breaker to the on
position.