214075
21
Revision A
Figure 3.23: Hydraulic Center-Link
6.
Adjust position of the center-link cylinder (A) with the
REEL UP and REEL DOWN switches on the GSL until
the hook is positioned above the header
attachment pin.
IMPORTANT:
Hook release must be down to enable self-locking
mechanism. If the release is open (up), manually push it
down after hook engages header pin.
7.
Lower center-link (A) onto the header with REEL
DOWN switch until it locks into position (hook
release [B] is down).
8.
Check that center-link is locked onto header by
pressing the REEL UP switch on the GSL.
CAUTION
Check to be sure all bystanders have cleared the area.
Figure 3.24: Ground Speed Lever
9.
Press the HEADER UP switch (A) to raise header to
maximum height.
NOTE:
If one end of the header does
NOT
fully rise, rephase
the lift cylinders as follows:
•
Press and hold the HEADER UP switch until both
cylinders stop moving.
•
Continue to hold the switch for 3–4 seconds.
Cylinders are now phased.
NOTE:
It may be necessary to repeat this procedure if there is air in
the system.